Results 11 to 20 of about 1,976 (165)

Multi-objective optimal scheduling strategy for wind power, PV and pumped storage plant in VSC-HVDC grid

open access: yesThe Journal of Engineering, 2019
Zhangbei demonstration project will be the world's highest voltage level and largest capacity VSC-HVDC power grid, by which millions of kilowatts of renewable energy and pumped storage power will be supplied to Beijing.
Man Xu, Linlin Wu, Hui Liu, Xiao Wang
doaj   +1 more source

Insulator fault feature extraction system of substation equipment based on machine vision

open access: yesIET Networks, EarlyView., 2022
Abstract The artificial intelligence technology and intelligent automation are more and more widely used, the insulators play a supporting and insulating role in the operation of the grid. The use of machine vision inspection technology to detect insulator faults has become an inevitable trend of the times.
Keruo Jiang   +4 more
wiley   +1 more source

Research on overvoltage and minimum air clearance on 1000 kV AC side of converter transformer in ±1100 kV Guquan converter station

open access: yesThe Journal of Engineering, 2019
In the hierarchically connected ultra-high voltage (UHV) DC projects, the minimum air clearance on the 1000 kV AC side of converter transformer directly affects the layout and area of the valve hall.
Lou Ying   +3 more
doaj   +1 more source

Distributed wireless network resource optimisation method based on mobile edge computing

open access: yesIET Networks, EarlyView., 2022
This paper mainly compares the network ranking leader, consumption amount and network signal reception of the three algorithms. The study found that in terms of network sort captain, there are significant differences between the CPLEX algorithm, the CCST algorithm, and edge computing methods. The CCST algorithm and edge computing have little difference
Jiongting Jiang   +4 more
wiley   +1 more source

Calculation and protection on the lighting intruding waves of 550 kv GIS substation

open access: yesThe Journal of Engineering, 2018
Electromagnetic Transient Programme has been used to calculate the lightning intruding wave of 550 kV GIS substation. The effects of mode operation, surge impedance and length of cable have been considered in the process of calculation.
Dongpeng Sui   +5 more
doaj   +1 more source

Classification of common discharges in outdoor insulation using acoustic signals and artificial neural network

open access: yesHigh Voltage, 2019
Condition monitoring of outdoor insulation systems is crucial to the integrity of distribution and transmission overhead lines and substations. The objective of this study is to use a commercial acoustic sensor along with artificial neural network (ANN),
Satish Polisetty   +4 more
doaj   +1 more source

Assessment method for identification of electrical connectivity and thermal stability of power grid

open access: yesThe Journal of Engineering, 2019
Primary equipment failure in substation has a significant impact on the reliability of the power supply, and even threatens the thermal stability of power grid.
Yao-Yu Xu   +5 more
doaj   +1 more source

Effects of Aging on Condition of In-Service Transformer Oil: The Study Case of 150 kV/20 kV Substations in Crete

open access: yesEnergies
The effect of aging on the condition of the oil and the insulating paper of transformers, based on the oil analysis of a fleet of 150 kV/20 kV power transformers, is presented in this paper.
Nikolaos Mavrikakis, Kiriakos Siderakis
doaj   +1 more source

Condition Assessment of Field-Aged Composite Insulators Following Incidents of Insulator Flashunder

open access: yesEnergies
A condition assessment of a group of field-aged insulators operated for only 6 years on the island of Rhodes after incidents of intense electrical activity is presented in this paper.
Nikolaos Mavrikakis, Kiriakos Siderakis
doaj   +1 more source

Reliability of supply of switchgear for auxiliary low voltage in substations extra high voltage to high voltage [PDF]

open access: yesTehnika, 2015
Switchgear for auxiliary low voltage in substations (SS) of extra high voltages (EHV) to high voltage (HV) - SS EHV/HV kV/kV is of special interest for the functioning of these important SS, as it provides a supply for system of protection and other ...
Perić Dragoslav M.   +1 more
doaj   +1 more source

Home - About - Disclaimer - Privacy