Results 61 to 70 of about 18,644 (181)
Development of online monitor for substation 10 kV MOA
Metal oxide arresters (MOA) are widely used for over-voltage protection of power facilities in 10 kV distribution networks, and it is hard to determine the failure ones. This study presented an online monitor for 10 kV MOA used in substation.
Xinming Song +4 more
doaj +1 more source
PowerGPT‐R1: Vision‐Language Reinforcement Fine‐Tuning With Verifiable Reward for Power Inspection
ABSTRACT Vision‐driven intelligent power inspection systems have long faced the challenge of scarce high‐quality datasets in specialised domains, leading to limited performance of traditional deep learning methods (e.g., Faster‐RCNN) in few‐shot learning scenarios. Recent breakthroughs in language models, particularly the open‐source DeepSeek‐R1 model,
Yangyang Zhong +12 more
wiley +1 more source
The studies on strategies for improving restoration times in electrical distribution systems are extensive. They have theoretically explored the application of mathematical models, the implementation of remotely controlled systems, and the use of digital
Carlos Sánchez-Ixta +3 more
doaj +1 more source
ABSTRACT With the development of electric power artificial intelligence (AI) technology, many complicated challenges emerged during application. Traditional AI algorithms work well in specialised tasks such as detection and classification. However, they are unlikely to solve general problems.
Yuanpeng Tan +4 more
wiley +1 more source
STANDARDS IN CONTROL AND PROTECTION TEHNOLOGY FOR ELECTRIC POWER SYSTEMS [PDF]
The features of the standard IEC 16850 with respect to intelligent applications in substations are summarized. It is shown how modeling of functions independently from its allocation to devices allows optimizing existing applications and opening up for ...
Sergiu St. ILIESCU +3 more
core +2 more sources
Research on optimisation of minimum air clearance of 1000 kV UHV AC substation
Based on air clearance discharge characteristic curve and insulation coordination method, it is pointed out that the minimum air clearance of 1000 kV ultra-high voltage (UHV) AC substation can be further optimised.
Li Zhenqiang +3 more
doaj +1 more source
ABSTRACT Radiative cooling holds potential for outdoor transformers in operation due to its zero‐energy consumption and high adaptability and has demonstrated effective heat dissipation in simulations of small distribution transformers. Accurate calculation of the transformer temperature rise and the radiative cooling effect is crucial for practical ...
Guoqiang Gao +7 more
wiley +1 more source
In hierarchically connected UHV DC projects, the 1000 kV AC filter sub-bank in converter station is provided with two 500 kV circuit breakers. To determine the test DC component decay time constant when breakers break short-circuit current, relevant DC ...
Li Zhenqiang +3 more
doaj +1 more source
An Investigation into Substation Grounding and Its Implementation on Gaza Substation
An investigation into the optimal design of a substation grounding system for the transmission substation in Gaza City, Palestine has been carried out. A research into the most influential parameters on the effectiveness of the substation grid system has been performed and its results have been incorporated into the Gaza case study.
Ahmed Hammuda +2 more
openaire +2 more sources
ABSTRACT The direct effects of lightning strikes on forest combustibles form the foundation for predicting lightning‐induced forest fires. Accurate assessment of lightning impact is hindered by limited knowledge of the conduction characteristics of standing larch trees.
Jinru Sun +5 more
wiley +1 more source