Auxiliary services are vital for the operation of a substation. If a contingency affects the distribution feeder that provides energy for the auxiliary services, it could lead to the unavailability of the substation’s service.
Alejandra Tabares +5 more
doaj +1 more source
In the hierarchically connected ultra-high voltage (UHV) DC projects, the minimum air clearance on the 1000 kV AC side of converter transformer directly affects the layout and area of the valve hall.
Lou Ying +3 more
doaj +1 more source
Generalised resilience models for power systems and dependent infrastructure during extreme events
This study presents a generalised critical infrastructures resilience model for extreme events with a focus on power grids. Infrastructures are modelled as three domains – physical, cyber, and human.
Vaidyanathan Krishnamurthy +5 more
doaj +1 more source
The effect of aging on the condition of the oil and the insulating paper of transformers, based on the oil analysis of a fleet of 150 kV/20 kV power transformers, is presented in this paper.
Nikolaos Mavrikakis, Kiriakos Siderakis
doaj +1 more source
Impact analysis of traction loads on power grid based on probabilistic three-phases load flow
Electrified railway traction power supply system is directly powered by 110 kV or 220 kV (some 330 kV) high-voltage power grid. The uncertainty, non-linearity, and asymmetry of traction loads like the electric locomotives and electric multiple units ...
Yulong Che +5 more
doaj +1 more source
In large substations, many lightning rods are installed on multi-grounded frames. The lightning rods, the frame, the grounding grid and the soil form a whole body, and the lightning current will be discharged from many grounding points.
Zhuoran Liu, Weidong Shi, Bo Zhang
doaj +1 more source
Condition Assessment of Field-Aged Composite Insulators Following Incidents of Insulator Flashunder
A condition assessment of a group of field-aged insulators operated for only 6 years on the island of Rhodes after incidents of intense electrical activity is presented in this paper.
Nikolaos Mavrikakis, Kiriakos Siderakis
doaj +1 more source
Environmentally Friendly Compact Air-Insulated High-Voltage Substations
This paper investigates the possible options for achieving a substantial reduction in a substation footprint using air-insulated switchgear as a more environmentally-friendly alternative to gas-insulated substations that use SF6 gas.
Maurizio Albano +3 more
doaj +1 more source
Load flow, short circuit and motor starting studies in electrical power substations.
Power system studies are essential for the proper planning and design of electrical power substations. This paper presents the load flow, short circuit, and motor starting studies for 33/6.6/0.44 kV electrical power substation.
Mohan Muniappan
doaj +1 more source
Research on automatic location and recognition of insulators in substation based on YOLOv3
With the development of a smart grid, the automatic location of power equipment is becoming a trend. In this study, a method for automatic location identification and diagnosis of external power insulation equipment based on YOLOv3 is proposed. This deep
Yunpeng Liu +6 more
doaj +1 more source