Results 41 to 50 of about 1,655 (182)
The prefabricated subway station is composed of prefabricated components and cast-in-place concrete, there are many splicing nodes between its components, and these splicing nodes will directly affect the seismic performance of the structure.
ZHONG Zilan, TANG Junchao, CHEN Jinnan, XU Chengshun, DU Xiuli
doaj +1 more source
In this paper, a seismic and vibration reduction measure of subway station is developed by setting a segmented isolation layer between the sidewall of structure and the diaphragm wall.
Zhidong Gao +3 more
doaj +1 more source
Numerical simulation of irregular section underground structure shaking table test model
Based on the the large shaking table test results on irregular section subway station structure in soft soil, an overall time-history numerical simulation is conducted to study the nonlinear dynamic interaction of the soil-irregular underground structure.
Baizan Tang +4 more
doaj +1 more source
Spatial Effect Analysis on Shaking Table Tests of Subway Station Structure in Liquefiable Ground
Based on the test data of shaking table tests of subway station structure in liquefiable ground under both near-field and far-field earthquakes, the spatial effects of dynamic pore water pressure (PWP)and peak ground acceleration (PGA)of liquefiable ...
Guo Xing Chen +4 more
core +1 more source
Collapse modeling of a subway station structure in seismic subsidence site under strong mainshock-aftershock sequences [PDF]
When strong earthquakes occur, the mainshock can trigger aftershocks in a short period, causing additional damage to structures. However, the complex dynamic characteristics of seismic subsidence site make this problem more challenging.
Pak, Ronald Y.S. +4 more
core +1 more source
The excavation depth of a deep and large foundation pit of a composite support system is 25.5 m, the minimum clear distance from the main structure of the station is 10.6 m and the closest distance to the entrance and exit structure is only 3.6 m ...
Hua Peng +5 more
doaj +1 more source
Data Acquisition Technology of Large Scale Shaking Table Test of Subway Station Structure
Based on latest improvement of shaking table test of subway station structure, the paper carries out an experiment to verify the monitoring and data acquisition technology in the shaking table test.
Bian, Jin, Tao, Lianjin, Huang, Jun
core +1 more source
Response Displacement Method for Seismic Calculation of Subway Station Complex Structure of TOD Mode
The TOD mode with rail transit stations as the center has become an important direction of future central city construction. However, at present, there is still a lack of simplified calculation methods for the seismic design of a subway station complex ...
Junhai An +3 more
doaj +1 more source
Review of researches on seismic response of close underground crossing structures
In view of the design and use requirements, a large number of close underground crossing projects have emerged, forming a complex interaction system between soil-crossing structural groups. When a number of underground structures are close to each other,
WANG Guo-bo 1,2, PENG Xiang-jun 1, HAO Peng-fei 1, WEI Hao-hao 1
doaj +1 more source
Interchange Renovation Construction Technology of Beijing Subway Line 10 Xitucheng Station
Objective Taking the interchange renovation construction of Beijing Subway Line 10 Xitucheng Station as example, the construction scheme for interchange renovation in existing station without reserved transfer conditions is studied.
YE Xinfeng +5 more
doaj +1 more source

