Results 211 to 220 of about 119,668 (266)
What endourology can learn from urodynamics: towards safe and standardized intrarenal pressure monitoring and use of suction irrigation pressure auto-regulating systems (SIPS). [PDF]
Dybowski B, Somani BK, Bres-Niewada E.
europepmc +1 more source
Clinical efficacy of the Galdakao-modified supine Valdivia position vs. the lithotomy position in FANS-UAS-assisted IPC-RIRS for renal calculi. [PDF]
Zhu Q +6 more
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Acta Neurochirurgica, 1980
Conventional suction systems for neurosurgery are assessed against the background of findings in experimental investigations. Criteria for optimum suction are proposed. The advantages of a modified suction system for neurosurgery are discussed, and recommendations are given.
B, Vällfors +3 more
openaire +2 more sources
Conventional suction systems for neurosurgery are assessed against the background of findings in experimental investigations. Criteria for optimum suction are proposed. The advantages of a modified suction system for neurosurgery are discussed, and recommendations are given.
B, Vällfors +3 more
openaire +2 more sources
SPE European Petroleum Conference, 1978
Abstract The development of self-burying suction anchors is described and data on pull-out forces presented for both inverted-cup and solid hemispherical types embedded in fine sand at depths up to three times anchor diameter. Observations made during sea trials of both anchor types are discussed.
Quentin Wilson, Baldev Sahota
openaire +1 more source
Abstract The development of self-burying suction anchors is described and data on pull-out forces presented for both inverted-cup and solid hemispherical types embedded in fine sand at depths up to three times anchor diameter. Observations made during sea trials of both anchor types are discussed.
Quentin Wilson, Baldev Sahota
openaire +1 more source
Pediatrics, 1987
To the Editor.— With reference to Dr Eisner's comment (Pediatrics 1986;78:713) that it is technically difficult to intubate a neonate's trachea with a large suction catheter, I would reply that our neonatology group has enjoyed good success in suctioning meconium from below the cords in more than 1,600 meconium deliveries during the past
openaire +2 more sources
To the Editor.— With reference to Dr Eisner's comment (Pediatrics 1986;78:713) that it is technically difficult to intubate a neonate's trachea with a large suction catheter, I would reply that our neonatology group has enjoyed good success in suctioning meconium from below the cords in more than 1,600 meconium deliveries during the past
openaire +2 more sources

