Results 61 to 70 of about 902,197 (304)
In a rat model of bypass DuraGraft ameliorates endothelial dysfunction of arterial grafts
Coronary artery bypass surgery can result in endothelial dysfunction due to ischemia/reperfusion (IR) injury. Previous studies have demonstrated that DuraGraft helps maintain endothelial integrity of saphenous vein grafts during ischemic conditions.
Shuo Lian +9 more
doaj +1 more source
Successful Treatment of Whole Coronary Artery Spasm after Off-Pump Coronary Artery Bypass Grafting
Coronary artery spasm after coronary artery bypass grafting is a rare but life-threatening condition. Herein, we report the case of a 77-year-old man who received off-pump coronary artery bypass grafting.
Akihiro Kobayashi +3 more
doaj +1 more source
Coronary artery grafting in infants [PDF]
Coronary artery bypass grafting (CABG) with cardiac vale repair is an uncommon surgery in infants. CABG is technically demanding in infants due to the small size not only of the coronary arteries but also the potential graft arteries.
Maskari, Salim +3 more
core
Modified Glucose-Insulin-Potassium Regimen Provides Cardioprotection With Improved Tissue Perfusion in Patients Undergoing Cardiopulmonary Bypass Surgery [PDF]
Background Laboratory studies demonstrate glucose-insulin-potassium (GIK) as a potent cardioprotective intervention, but clinical trials have yielded mixed results, likely because of varying formulas and timing of GIK treatment and different clinical ...
Chen, Wensheng +12 more
core +1 more source
Minimally Invasive Mitral Valve Surgery II: Surgical Technique and Postoperative Management. [PDF]
Techniques for minimally invasive mitral valve repair and replacement continue to evolve. This expert opinion, the second of a 3-part series, outlines current best practices for nonrobotic, minimally invasive mitral valve procedures, and for ...
Agnihotri, Arvind K +25 more
core +1 more source
Screen‐Printed Flexible Piezoelectric Force Sensor Array with Electromagnetic Interference Shielding
This article introduces a flexible screen‐printed piezoelectric sensor array designed for low‐frequency healthcare applications such as tactile sensing and cardiovascular monitoring. The device integrates interface electronics enabling the simultaneous acquisition of up to 128 signals, along with flexible EMI shielding that significantly reduces noise ...
Joseph Faudou +6 more
wiley +1 more source
Background This study investigated the impact of preoperative right ventricular (RV) dysfunction and dilatation on survival outcomes following left ventricular surgical restoration (LVSR) in patients with ischemic cardiomyopathy. A retrospective analysis
Abdelhameed Elsayed +7 more
doaj +1 more source
Tying the knot: An uncommon complication
Cardiothoracic procedures require continuous hemodynamic monitoring and a fair proportion of these require the insertion of a pulmonary artery catheter, known also as Swan‐Ganz catheter. Given, however, the invasive nature of these procedures, unforeseen
Konstantinos Boumpoulis +4 more
doaj +1 more source
A 31-year-old female patient with a previous history of Carney complex and surgical resection for cardiac myxoma and bilateral adrenalectomy at 18 years old and 10 and 11 years old, respectively, was referred to our department with a diagnosis of ...
Daniel Grandmougin +6 more
doaj +1 more source
Biofabrication aims at providing innovative technologies and tools for the fabrication of tissue‐like constructs for tissue engineering and regenerative medicine applications. By integrating multiple biofabrication technologies, such as 3D (bio) printing with fiber fabrication methods, it would be more realistic to reconstruct native tissue's ...
Waseem Kitana +2 more
wiley +1 more source

