Results 141 to 150 of about 72,904 (298)
Abstract Background Left atrial enlargement (LAE) is predictive of cardiovascular morbidity and mortality. Prior studies of point‐of‐care ultrasound (POCUS) interpretation methods for identifying LAE utilized older echocardiographic reference ranges. Objectives Compare the test characteristics of hospitalist‐performed POCUS techniques for identifying ...
Christopher J. Smith +7 more
wiley +1 more source
Central illustration: Sex‐based differences in outcomes between male and female patients with bicuspid aortic stenosis following transcatheter aortic valve replacement. Abstract Bicuspid aortic valve (BAV) is a common congenital anomaly leading to early aortic stenosis.
Muhammad Huzaifa Ahmed Khan +12 more
wiley +1 more source
On-pump fibrillating heart mitral valve replacement with the SAPIEN™ XT transcatheter heart valve [PDF]
In some high-risk patients, standard mitral valve replacement can represent a challenging procedure, requiring a risky extensive decalcification of the annulus. In particular, high-risk redo patients and patients with a previously implanted transcatheter
Ferrari, Enrico +3 more
core
Summary Introduction Uncertainty remains regarding whether the time of day that cardiac surgery is performed affects postoperative outcomes or if the observed variation can be explained by patient or surgical factors. Methods A secondary analysis of prospectively collected data was conducted to examine the association between time of cardiac surgery ...
Gareth Kitchen +11 more
wiley +1 more source
A 31-year-old woman with left ventricular (LV) assist device (LVAD) support presented with refractory ventricular arrhythmias attributed to severe aortic insufficiency and inadequate left ventricular offloading.
Katlin T. Schmitz, MD +3 more
doaj +1 more source
Hydraulic In Vitro Characterization of MR‐Conditional Blood Pumps
Cardiac surgery in neonates requires close placement of cardiopulmonary bypass machines due to limited blood volume, complicating MR compatibility. This study introduces three MR‐conditional blood pump prototypes. None interfered with MRI imaging, though RF‐related sensor effects remain untested.
Dominik T. Schulte +6 more
wiley +1 more source
Transcatheter aortic valve replacement
Anneke Damberg, Carina Benstoem, Ruediger Autschbach, Andreas GoetzenichDepartment of Cardiovascular and Thoracic Surgery, University Clinic RWTH Aachen, Aachen, GermanyAbstract: The standard treatment for symptomatic severe aortic valve stenosis is ...
Damberg A +3 more
doaj
Bicuspid Aortic Valve Disease: Classifications, Treatments, and Emerging Transcatheter Paradigms
Bicuspid aortic valve (BAV) is a common congenital valvular malformation, which may lead to early aortic valve disease and bicuspid-associated aortopathy. A novel BAV classification system was recently proposed to coincide with transcatheter aortic valve
Ankur Kalra, MD +11 more
doaj +1 more source
Surgical or Transcatheter Aortic-Valve Replacement
Noble, Stéphane Laurent +2 more
openaire +7 more sources
Aspirin discontinuation in long‐term, stable Heart Mate 3 LVAD patients maintained on Vitamin K antagonists did not increase hemocompatibility‐related adverse events. These findings support the safety of simplified antithrombotic therapy and extend randomized evidence for aspirin avoidance to the long‐term management of Heart Mate 3 recipients ...
Melanie Arnreiter +8 more
wiley +1 more source