Results 61 to 70 of about 1,105,267 (283)
Interfacial charge transfer and low‐resistance interphase formation between PEO‐based polymer and Li10GeP2S12 solid electrolytes are investigated using multi‐electrode impedance spectroscopy and advanced analytical techniques such as XPS and ToF‐SIMS.
Ujjawal Sigar +6 more
wiley +1 more source
Pair of gloves of kidskin leather; off-white; wrist length. Back of each glove decorated with serpentine cut that is stitched closed with yellow thread, and with nine rows of 3 seed beads each, the rows alternating on sides of the cut. Unlined.
Barra Gloves
core
Recent Advances of Slip Sensors for Smart Robotics
This review summarizes recent progress in robotic slip sensors across mechanical, electrical, thermal, optical, magnetic, and acoustic mechanisms, offering a comprehensive reference for the selection of slip sensors in robotic applications. In addition, current challenges and emerging trends are identified to advance the development of robust, adaptive,
Xingyu Zhang +8 more
wiley +1 more source
Hierarchical multi‐material TPMS lattices are engineered as flexible tactile sensors by combining soft and stiff elastomeric layers with a conformal conductive coating. The bilayer architecture delivers sensitivity at low pressures while maintaining a broad detectable range under large loads, enabling reliable pressure and vibration monitoring for ...
Reza Noroozi +3 more
wiley +1 more source
Case Study Of Surgical Gloves In Malaysia
This paper traces the history of Innovative Polymer, examines the internal and external environments in which it operates, evaluating its strength, weaknesses, opportunities and treats and finally formulating strategies to be employed to repositioned ...
Seng, Ng Lai
core +1 more source
Double gloving for self-protection in high-risk surgeries: a systematic review and meta-analysis
Background Double gloving is recommended for protecting surgical personnel from infections, but it is not a universal practice, especially in low- and middle-income countries where risk is very high.
Kumari Vandana Singh +3 more
doaj +1 more source
Evaluation of sterile glove usage on digital tactile sensitivity using the Grating Orientation Task
IntroductionSurgical glove use may be associated with a decrease in tactile sensitivity, with thicker gloves or double-gloving techniques further altering sensation.
Thomas O. Riegel +3 more
doaj +1 more source
Glove failure in elective thyroid surgery: A prospective randomized study
Objectives: To analyze perforation rate in sterile gloves used by surgeons in the operating theatre of the Department of Endocrinological and General Surgery of Medical University of Lodz. Material and Methods: Randomized and controlled trial. This study
Dariusz Timler +6 more
doaj +1 more source
Reduction of gastroschisis using a surgical glove in the absence of standard silos
Gastroschisis is a congenital abdominal wall defect with incidence of 1 in 4000 live births. The primary goal of treatment is to reduce bowel back to the abdominal cavity with minimizing risk of injury to the bowel or increased intra-abdominal pressure ...
Mohammad Akbar Shirzad +3 more
doaj +1 more source
Laser‐Induced Local De‐Doping in Organic Semiconductors
The polymer PBTTT‐C14 doped with the small molecule acceptor F4TCNQ is considered as a benchmark material system. Mask‐free, microscale patterning of the doping level via laser‐induced heating and sublimation of dopant molecules is shown. Controlling laser irradiance and swath spacing allows dopant level control with laser‐limited resolution, opening ...
Christian Rainer +5 more
wiley +1 more source

