Results 11 to 20 of about 15,311 (152)
Bacterial endophthalmitis following 25-gauge transconjunctival sutureless vitrectomy
Drew N Sommerville, Dean P HainsworthThe Mason Eye Institute, University of Missouri, Columbia, Missouri, USAPurpose: To report a case of endophthalmitis following 25-gauge transconjunctival sutureless vitrectomy.Design: Observational case report.Methods:
Drew N Sommerville, Dean P Hainsworth
exaly +3 more sources
Learning curve of sutureless transconjunctival 20-gauge vitrectomy [PDF]
Gilbert WS Simanjuntak,1,2 Arief S Kartasasmita,3,4 Ilias Georgalas,5 Eustratios V Gotzaridis6 1Department of Ophthalmology, Faculty of Medicine, Christian University of Indonesia, Jakarta, 2Cikini Eye Institute, Cikini CCI Hospital, Jakarta ...
Simanjuntak GWS +3 more
doaj +4 more sources
Sutureless vitrectomy has rapidly been accepted as an essential part of a vitreoretinal surgical setup. The size and structure of the wound along with near intact conjunctival covering makes the incision self-sealing and safe.
Warrier Sunil +3 more
doaj +3 more sources
Ahmed Abdel Alim Mohamed,1 Mohamed Abdrabbo21Ain Shams University, Faculty of Medicine, Ophthalmology Department, Cairo; 2Faculty of Medicine, Ophthalmology Department, Benha University, Benha, EgyptBackground: The purpose of this study was to assess the
Mohamed AA, Abdrabbo M
doaj +1 more source
Sympathetic ophthalmia after 23-gauge transconjunctival sutureless vitrectomy [PDF]
Masatoshi Haruta1, Hirokazu Mukuno2, Kazuaki Nishijima3, Hitoshi Takagi4, Mihori Kita51Department of Ophthalmology, Kurume University School of Medicine, Kurume, Fukuoka, Japan; 2Department of Ophthalmology, Konan Hospital, Kobe, Hyogo, Japan ...
Masatoshi Haruta +3 more
doaj +4 more sources
Primary 23-gauge sutureless vitrectomy for rhegmatogenous retinal detachment
Aims : To report a prospective non-comparative consecutive interventional study on the safety and efficacy of 23-Gauge transconjunctival sutureless pars plana vitrectomy for primary rhegmatogenous retinal detachment (RRD).
Mario R Romano +7 more
doaj +2 more sources
Jian-Guo Wu, Rui-Hua Wei, Ai-Hua Liu, Xiao-Xu Zhou, Guo-Ling Sun, Xiao-Rong LiTianjin Medical University Eye Center, Tianjin, ChinaBackground: The purpose of this prospective, interventional, comparative case series was to evaluate the efficiency and ...
Li X-R +5 more
doaj +1 more source
Upper Eyelid Silicone Oil Migration After Sutureless 23-Gauge Vitrectomy
To report a case of upper eyelid swelling and ptosis caused by silicone oil migration in a patient after sutureless 23-gauge pars plana vitrectomy and silicone oil injection.
Alireza Dehghani +3 more
doaj +2 more sources
A new approach for sutureless 20-G vitrectomy
Aim of the work To assess the safety and the effectiveness of a new approach for sutureless 20-G pars plana vitrectomy using N-butyl-2-cyanoacrylate ′Histoacryl′ glue, aiming for the conversion of the conventional 20-G vitrectomy to a sutureless ...
Dikran G Hovaghimian, Saleh Sherif Adel
doaj +2 more sources
Acute endophthalmitis following 23-gauge sutureless transconjunctival vitrectomy
We report a case that developed acute postoperative endophthalmitis after transconjunctival sutureless vitrectomy using the 23-gauge system. A 66-year-old man underwent non-sutured 23-gauge pars plana vitrectomy for epimacular membrane. Since the patient
Çekiç Osman +3 more
doaj +1 more source

