Results 81 to 90 of about 70,782 (245)
A flexible, skin‐integrated electromagnetic actuator is developed for wearable virtual/augmented reality (VR/AR) haptic systems. A tunable design model enables control over displacement and resonance frequency. The system is validated through a custom VR application with a 6 × 4 actuator array, demonstrating real‐time, spatially targeted tactile ...
Naji Tarabay +9 more
wiley +1 more source
Promoting Treg Polarization‐Mediated Anti‐Scar and Appendage Regeneration in Wound Healing
This study develops a PLGA@LA‐BMP4‐PG bilayer scaffold to address scar formation and appendage loss in skin repair. The piezoelectric PLA layer enhances cell migration via electric fields, while GelMA delivers LA promoting Tregs polarization and BMP4 inhibiting FBs differentiation.
Yiwen Yang +10 more
wiley +1 more source
A Wearable Brain–Computer Interface for Mitigating Car Sickness via Attention Shifting
Car sickness poses a major challenge in vehicular travel, yet effective nonpharmacological solutions are scarce. We developed a wearable, closed‐loop mindfulness BCI that uses real‐time EEG‐based neurofeedback to shift attention away from motion‐induced discomfort. Validated in real‐car experiments involving >100$>100$ susceptible individuals, over 83%
Jiawei Zhu +14 more
wiley +1 more source
The Role of Ionic Liquids at the Biological Interfaces in Bioelectronics
Ionic liquids (ILs) are highlighted as key artificial ionic materials that bridge biological ion‐based signaling and electronic devices. By understanding their composition, structure, function relationships, and mechanisms, ILs can advance from high performance electrolyte to core materials enabling integrated, multifunctional bioelectronics for ...
Yeong‐sinn Ye +5 more
wiley +1 more source
Introduction: This study was designed with the main purpose of examining the compatibility of the two indicators of wet bulb globe temperature (WBGT) and predicted thermal strain (PHS) in assessing the environmental conditions and the heat load imposed ...
Vahid Gharibi +3 more
doaj
General schematic of the approach. Abstract Conventional Silver/Silver Chloride (Ag/AgCl) electrodes remain the clinical standard for electrophysiological monitoring but are hindered by poor skin conformity, mechanical rigidity, and signal degradation, particularly under motion or sweat.
Nazmi Alsaafeen +11 more
wiley +1 more source
Tratamiento quirúrgico de la hiperhidrosis
El síndrome de hiperhidrosis esencial de los miembros superiores es una afección rara., que supone habitualmente un impedimento laboral o social importante.
Lorenzo Mérola, Hugo Malosetti
doaj
This study presents sulfate‐directed silver dendrites (s‐AgDs) as oxidation‐resistant SERS substrates with long‐term stability, reproducibility, and sub‐picomolar sensitivity. Sulfate ions guide anisotropic growth and protect the surface, enabling improved performance over 7 months under ambient conditions.
Aradhana Dwivedi +6 more
wiley +1 more source
Effect of Half Time Cooling on Thermoregulatory Responses and Soccer-Specific Performance Tests
This study examined two active coolings (forearm and hand cooling, and neck cooling) during a simulated half-time recovery on thermoregulatory responses and subsequent soccer-specific exercise performance.
Yang Zhang +7 more
doaj
IntroductionThe major pathophysiological symptom of the menopause affecting daily life is hot flushes, which are also associated with elevated cardiovascular disease risk.
Kirsty A. Roberts +6 more
doaj +1 more source

