Core Magnetization Effect in Sweep Frequency Response Analysis for Transformer Diagnosis
2015 Second International Conference on Advances in Computing and Communication Engineering, 2015Power transformer is one of the most prominent equipment in the area of power sector. Increasing power demand at world level requires manufacturing of large number of oil immersed power transformer. With increase in size and MVA rating of power transformer, the chances of failure also increases simultaneously.
Ambuj Kumar +4 more
openaire +2 more sources
2019 54th International Universities Power Engineering Conference (UPEC), 2019
Power transformer failures can lead to power outages and significant financial loss, particularly at high voltage and medium voltage levels. Frequency response analysis (FRA) is used to diagnose transformer faults and particularly so for detecting mechanical displacements in windings and core.
Anurag A. Devadiga +3 more
openaire +2 more sources
Power transformer failures can lead to power outages and significant financial loss, particularly at high voltage and medium voltage levels. Frequency response analysis (FRA) is used to diagnose transformer faults and particularly so for detecting mechanical displacements in windings and core.
Anurag A. Devadiga +3 more
openaire +2 more sources
IECON 2016 - 42nd Annual Conference of the IEEE Industrial Electronics Society, 2016
The Sweep Frequency Response Analysis (SFRA) is one of the powerful graphical technique to detect and diagnosed different faults in transformer. This paper proposed novel approach for the detection of winding fault and constructional asymmetry in three phase induction motor (TPIM) using sweep frequency response analysis technique.
Tushar Gulabrao Vilhekar +2 more
openaire +2 more sources
The Sweep Frequency Response Analysis (SFRA) is one of the powerful graphical technique to detect and diagnosed different faults in transformer. This paper proposed novel approach for the detection of winding fault and constructional asymmetry in three phase induction motor (TPIM) using sweep frequency response analysis technique.
Tushar Gulabrao Vilhekar +2 more
openaire +2 more sources
2007 IEEE Power Engineering Society Conference and Exposition in Africa - PowerAfrica, 2007
Sweep frequency response analysis (SFRA) is one of the most powerful diagnostic tools for assessing mechanical damage to a transformer winding. Analysis of the results, which are in the form of frequency response traces can, however, be daunting to new users. One approach is to attempt automated analysis, and this paper presents an approach using cross-
G.M. Kennedy +2 more
openaire +2 more sources
Sweep frequency response analysis (SFRA) is one of the most powerful diagnostic tools for assessing mechanical damage to a transformer winding. Analysis of the results, which are in the form of frequency response traces can, however, be daunting to new users. One approach is to attempt automated analysis, and this paper presents an approach using cross-
G.M. Kennedy +2 more
openaire +2 more sources
AIP Conference Proceedings, 2015
Power transformer had been a major asset in any power utilities since the last millennium. Transformer mechanical integrity is among the important part to be ensured in good condition. An assessment for Sweep Frequency Response Analysis (SFRA) traces to determine internal transformer conditions is presented in this paper. Three standards are identified
Z. H. Bohari +5 more
openaire +2 more sources
Power transformer had been a major asset in any power utilities since the last millennium. Transformer mechanical integrity is among the important part to be ensured in good condition. An assessment for Sweep Frequency Response Analysis (SFRA) traces to determine internal transformer conditions is presented in this paper. Three standards are identified
Z. H. Bohari +5 more
openaire +2 more sources
IEEE Power & Energy Society General Meeting, 2022
As inter-turn faults in transformer windings are the most severe, their delayed detection and localization may create extensive damage to the winding. Therefore, a new inter-turn fault localization methodology based on sweep frequency response analysis ...
Abhishek Kumar, B. Bhalja, G. Kumbhar
semanticscholar +1 more source
As inter-turn faults in transformer windings are the most severe, their delayed detection and localization may create extensive damage to the winding. Therefore, a new inter-turn fault localization methodology based on sweep frequency response analysis ...
Abhishek Kumar, B. Bhalja, G. Kumbhar
semanticscholar +1 more source
Modeling and diagnostic transformer condition using Sweep Frequency Response Analysis
2009 IEEE 9th International Conference on the Properties and Applications of Dielectric Materials, 2009Many methods have been developed to justify the condition of power transformer; one of the newest and well known is by using Sweep Frequency Response Analysis techniques. The basic concept of this method is by injecting a constant-amplitude of sinusoidal signal under various frequencies (sweep).
A. P. Purnomoadi, D. Fransisco
openaire +1 more source
A new technique for a better sweep frequency response analysis interpretation
2012 IEEE International Symposium on Electrical Insulation, 2012This paper presents a new technique for a better and faster sweep frequency response analysis (SFRA) results' interpretation. The proposed technique is based on the time-frequency analysis. Unlike the Fourier transform (FT) which is a 1-dimensional representation, a time-frequency distribution (TFD) is a 2-dimensional representation where both time and
Esam Al Murawwi, Braham Barkat
openaire +1 more source
Statistical evaluation of a new technique for Sweep Frequency Response Analysis
2012 IEEE International Conference on Power and Energy (PECon), 2012This paper presents a statistical evaluation of a new technique for Sweep Frequency Response Analysis (SFRA). The new technique is based on the time-frequency distribution (TFD). Unlike the Fourier transform based (SFRA) which is a 1-dimensional representation, a TFD is a 2-dimensional representation where both time and frequency are present in one ...
Esam Al Murawwi +2 more
openaire +1 more source
IEEE Transactions on Instrumentation and Measurement, 2023
Winding inter-turn and ground short circuit (SC) faults are common fault types of synchronous machines. The sweep frequency response analysis (SFRA) has been recently introduced to detect winding SC faults.
Yu Chen +4 more
semanticscholar +1 more source
Winding inter-turn and ground short circuit (SC) faults are common fault types of synchronous machines. The sweep frequency response analysis (SFRA) has been recently introduced to detect winding SC faults.