MECHANICAL CONDITION ASSESSMENT OF TNB IN-SERVICE DISTRIBUTION TRANSFORMERS USING SWEEP FREQUENCY RESPONSE ANALYSIS (SFRA) [PDF]

open access: yes, 2012
Distribution transformers in TNB (Tenaga Nasional Berhad) are exposed to the thermal and electrical stresses. Those stresses are effecting to the main mechanical active parts in transformer such as core and winding.
Ab Ghani, Sharin   +4 more
core  

Improving the Power System safety in Hospitals by means of periodical SFRA tests on Medical Isolation Transformers [PDF]

open access: yes, 2020
The paper has the main aim of demonstrating a possible use of the well consolidated monitoring SFRA (Sweep Frequency Response Analysis) technique for preventive maintenance procedure applied to isolation medical transformers operating in hospitals’ group
A. Fioravanti   +4 more
core  

Assessing moisture content in XLPE power cables using frequency-dependent tangent delta measurements

open access: yesMaterials Research Express
The reliability of cross-linked polyethylene (XLPE)-insulated power cables, mostly used for electricity distribution and transmission in urban areas, is often compromised due to the lack of effective condition-based monitoring systems.
Babu Naik Gugulothu   +4 more
doaj   +1 more source

Performing reliable and reproducible frequency response measurements on power transformers [PDF]

open access: yes, 2018
The Sweep Frequency Response Analysis (SFRA) has become a standard method to assess the mechanical and electrical integrity of the power transformer’s active part.
Michael RÄDLER, Stephanie UHRIG
core   +1 more source

Diagnostic methods of frequency response analysis for power transformer winding a review [PDF]

open access: yes, 2016
: Monitoring and diagnosis of power transformers in power systems have been investigated and discussed for the past decades. Earlier detect power transformer winding failures is recommended for both manufacturing process and also for power system ...
Nicolae, Dan-Valentin, Nnachi, G. U.
core   +3 more sources

SWEEP FREQUENCY RESPONSE ANALYSIS (SFRA) AN APPROACH TO DETECT HIDDEN TRANSFORMER FAULTS [PDF]

open access: yes, 2020
: Sweep frequency response analysis is a major advance in transformer condition analysis. Frequency response is performed by applying a low voltage signal of varying frequencies to the transformer windings and measuring both the input and output signals.
Akshay A Pandya, B R Parekh, PROF.) D R
core  

Understanding SFRA Results using Transformer Model with Simulated Faults [PDF]

open access: yes, 2013
Sweep Frequency Response Analysis (SFRA) is well known power transformer diagnostics device which capable on detected faults/changes either electrical or mechanical.
Ab Ghani, Sharin   +3 more
core  

Assessment of transformer health index using different model [PDF]

open access: yes, 2017
Transformer failures lead to interruption of power supply. Therefore, asset management is important to monitor the efficient functioning of transformers.
Azis, Norhafiz   +4 more
core  

Sweep Frequency Response Analysis for Assessment Deformation Core at Power Transformer [PDF]

open access: yes
SFRA (Sweep Frequency Response Analysis) is a transportation test where one of the purposes of this test is to ensure that the core of the power transformer does not shift due to the journey from the factory to the field. The SFRA testing is divided into
Dharmanto, Asep   +3 more
core   +2 more sources

A review of transformer FRA measurement and diagnosis techniques [PDF]

open access: yes, 2023
Frequency Response Analysis (FRA) is a successful technique to detect mechanical damage in power transformers with greater sensitivity than other measurements.
Ekanayake, Chandima   +8 more
core   +1 more source