2022 IEEE International Conference in Power Engineering Application (ICPEA), 2022
Electromagnetic waves on Partial Discharge (PD) that occur in Gas Insulated Switchgear (GIS) have frequency value in Ultra High Frequency (UHF) range (300 MHz – 3 GHz). So that, PD waves in GIS can be detected using UHF Antenna sensor. In this paper, the
Taufik Rhamdhani, U. Khayam, A. Zaeni
semanticscholar +1 more source
Electromagnetic waves on Partial Discharge (PD) that occur in Gas Insulated Switchgear (GIS) have frequency value in Ultra High Frequency (UHF) range (300 MHz – 3 GHz). So that, PD waves in GIS can be detected using UHF Antenna sensor. In this paper, the
Taufik Rhamdhani, U. Khayam, A. Zaeni
semanticscholar +1 more source
IEEE Transactions on Power Delivery
Switchgear is one of the key equipment in power grids. A proper maintenance strategy maximizes the cost-efficiency of switchgear maintenance expenses, meanwhile minimizing the power grid failure risk.
Nan Zhou, Yan Xu
semanticscholar +1 more source
Switchgear is one of the key equipment in power grids. A proper maintenance strategy maximizes the cost-efficiency of switchgear maintenance expenses, meanwhile minimizing the power grid failure risk.
Nan Zhou, Yan Xu
semanticscholar +1 more source
Trends in High Voltage Switchgear Research and Technology
IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERINGHigh voltage switchgear is an essential element for the transformation of energy systems towards sustainable and low carbon footprint technologies by electrification of society and industry.
Martin Seeger +5 more
semanticscholar +1 more source
IEEE Transactions on Power Delivery
Currently, almost all high-voltage switchgear and gas-insulated systems (GIS) are filled with SF6 under pressure. Accidental leakage of SF6 has dramatic effects on both the environment and the equipment itself.
E. Fylladitakis, Antonios X. Moronis
semanticscholar +1 more source
Currently, almost all high-voltage switchgear and gas-insulated systems (GIS) are filled with SF6 under pressure. Accidental leakage of SF6 has dramatic effects on both the environment and the equipment itself.
E. Fylladitakis, Antonios X. Moronis
semanticscholar +1 more source
IEEE Transactions on Components, Packaging, and Manufacturing Technology, 2022
Corona discharge occasionally occurs to the contact box of switchgear due to condensation under high humidity and pollution conditions, which may result in a switchgear insulation fault.
Shengwen Shu +5 more
semanticscholar +1 more source
Corona discharge occasionally occurs to the contact box of switchgear due to condensation under high humidity and pollution conditions, which may result in a switchgear insulation fault.
Shengwen Shu +5 more
semanticscholar +1 more source
2022 4th International Conference on Smart Power & Internet Energy Systems (SPIES), 2022
Moisture and condensation in high voltage switchgear will cause corrosion of parts, degradation of insulation performance and surface discharge.
Shen Genqiang +5 more
semanticscholar +1 more source
Moisture and condensation in high voltage switchgear will cause corrosion of parts, degradation of insulation performance and surface discharge.
Shen Genqiang +5 more
semanticscholar +1 more source
2024 IEEE 7th International Electrical and Energy Conference (CIEEC)
High-voltage switchgear is widely used in power transmission and distribution networks, and its temperature rise performance under long-term electrification is directly related to the safety and reliability of power supply.
Wenqiang Yang +5 more
semanticscholar +1 more source
High-voltage switchgear is widely used in power transmission and distribution networks, and its temperature rise performance under long-term electrification is directly related to the safety and reliability of power supply.
Wenqiang Yang +5 more
semanticscholar +1 more source
Review of Scientific Instruments
Medium-voltage (MV) switchgear and gas insulated switchgear (GIS) are essential components of power-grid systems. Their safe operation is crucial for the electricity consumption of users.
Xutao Han +7 more
semanticscholar +1 more source
Medium-voltage (MV) switchgear and gas insulated switchgear (GIS) are essential components of power-grid systems. Their safe operation is crucial for the electricity consumption of users.
Xutao Han +7 more
semanticscholar +1 more source
A Comparison of PD Detection Techniques for Complete Assemblies of Air-Insulated Switchgear
Electrical Insulation Conference, 2022This publication presents a comparison between conventional PD measurements, TEV PD detection and ultrasonic PD detection applied on medium-voltage air-insulated switchgear.
M. Lachance, Francis Rosa
semanticscholar +1 more source
A Linear Capacitive Sensor for ppm Moisture Measurement in SF₆ Gas-Insulated Switchgear
IEEE Transactions on Instrumentation and Measurement, 2021Moisture measurement and control is very essential for gas-insulated switchgear (GIS). For safe and reliable operation, the moisture inside GIS needs to be kept within the prescribed limit. This article presents a capacitive sensor for traces of moisture
Z. H. Zargar +3 more
semanticscholar +1 more source