IEEE Transactions on Instrumentation and Measurement
Withdrawable circuit breakers (CBs) rely on plum contacts in medium-voltage switchgears, but loose connections during insertion can cause fires or explosions at the making moment. Although loose connections lead to rising temperatures, traditional steady-
Mohsen Taghizadeh Kejani +3 more
semanticscholar +1 more source
Withdrawable circuit breakers (CBs) rely on plum contacts in medium-voltage switchgears, but loose connections during insertion can cause fires or explosions at the making moment. Although loose connections lead to rising temperatures, traditional steady-
Mohsen Taghizadeh Kejani +3 more
semanticscholar +1 more source
Bibliography of Switchgear Literature
IEEE Transactions on Power Apparatus and Systems, 1972This bibliography was prepared for the IEEE Education, Recognition and Planning Subcommittee of the IEEE Switchgear Committee to be used as a reference for switchgear education. The references essentially cover the period of time from 1975 through 1979 with a few papers preceding this period.
openaire +1 more source
Partial discharge detection and diagnosis in gas insulated switchgear: State of the art
IEEE Electrical Insulation Magazine, 2019Power utilities are struggling to reduce power failure incidents in substations and their components to operate more reliably and economically [1].
Qasim Khan +3 more
semanticscholar +1 more source
METHOD FOR OPERATING A SWITCHGEAR PANEL FOR ELECTRICAL SWITCHGEAR
2012A method for operating a switchgear panel (10) for electrical switchgear is described. The switchgear panel (10) has a plurality of electrical components, particularly circuit breakers, isolator/earthing switches or the like. Sensors for measuring operating variables are present, particularly for measuring currents, voltages, temperatures, periods or ...
SCHNEIDER ELECTRIC SACHSENWERK +2 more
openaire +2 more sources
Conference Record on Pulp and Paper Industry Technical Conference, 2003
The history of the development of power circuit breaker overcurrent trip devices from dashpots to digital circuit breakers is presented. The development of the retrofit circuit breaker concept is reviewed. The engineering considerations of retrofitting, economical benefits of retrofitting, sources and brands of retrofit kits, and problems with un-kit ...
openaire +1 more source
The history of the development of power circuit breaker overcurrent trip devices from dashpots to digital circuit breakers is presented. The development of the retrofit circuit breaker concept is reviewed. The engineering considerations of retrofitting, economical benefits of retrofitting, sources and brands of retrofit kits, and problems with un-kit ...
openaire +1 more source
Electroplating protects switchgear
Anti-Corrosion Manual, 1966Tin and tin/zinc plating is used to protect many copper, brass, and mild steel components of electrical switchgear, and to improve solderability. A new automatic plant is used by Yorkshire Switchgear Ltd.
openaire +1 more source
2004
It is not the purpose, or possible, within the scope of this book to provide a detailed step-by-step guide on the procedures to be followed when conducting development and type testing of switchgear. Indeed, such a guide would run into several volumes and, due to detailed changes in specifications that take place from time to time, it would quickly ...
openaire +1 more source
It is not the purpose, or possible, within the scope of this book to provide a detailed step-by-step guide on the procedures to be followed when conducting development and type testing of switchgear. Indeed, such a guide would run into several volumes and, due to detailed changes in specifications that take place from time to time, it would quickly ...
openaire +1 more source