Results 231 to 240 of about 30,341 (295)
Some of the next articles are maybe not open access.
IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2022
SF6 is a greenhouse gas. Finding an alternative gas for SF6 has become an urgent problem in the switch field. In order to explore the feasibility of replacing SF6 gas with dry air directly, CO2 and C4F7N/CO2 mixed gas, based on the KYN28‐12 medium ...
Lihua Zhao+8 more
semanticscholar +1 more source
SF6 is a greenhouse gas. Finding an alternative gas for SF6 has become an urgent problem in the switch field. In order to explore the feasibility of replacing SF6 gas with dry air directly, CO2 and C4F7N/CO2 mixed gas, based on the KYN28‐12 medium ...
Lihua Zhao+8 more
semanticscholar +1 more source
A Flexible Planarized Biconical Antenna for Partial Discharge Detection in Gas-Insulated Switchgear
IEEE Antennas and Wireless Propagation Letters, 2022This letter proposes a new ultrahigh frequency (UHF) flexible planar biconical antenna design method for partial discharge (PD) detection in gas-insulated switchgear. Continuous transverse branching increases the electrical length to expand the bandwidth
Guozhi Zhang+4 more
semanticscholar +1 more source
2022 IEEE International Conference in Power Engineering Application (ICPEA), 2022
Electromagnetic waves on Partial Discharge (PD) that occur in Gas Insulated Switchgear (GIS) have frequency value in Ultra High Frequency (UHF) range (300 MHz – 3 GHz). So that, PD waves in GIS can be detected using UHF Antenna sensor. In this paper, the
Taufik Rhamdhani, U. Khayam, A. Zaeni
semanticscholar +1 more source
Electromagnetic waves on Partial Discharge (PD) that occur in Gas Insulated Switchgear (GIS) have frequency value in Ultra High Frequency (UHF) range (300 MHz – 3 GHz). So that, PD waves in GIS can be detected using UHF Antenna sensor. In this paper, the
Taufik Rhamdhani, U. Khayam, A. Zaeni
semanticscholar +1 more source
Separation of Partial Discharge Faults in Metal-clad Switchgear Based on Pulse Shape Analysis
Electrical Insulation Conference, 2022Switchgear is an integral part of power systems network. Any fault occurring in switchgear may leads to significantly long outage duration and the affected load, or area, can be enormously large.
G. Hussain+3 more
semanticscholar +1 more source
IEEE Transactions on Components, Packaging, and Manufacturing Technology, 2022
Corona discharge occasionally occurs to the contact box of switchgear due to condensation under high humidity and pollution conditions, which may result in a switchgear insulation fault.
Shengwen Shu+5 more
semanticscholar +1 more source
Corona discharge occasionally occurs to the contact box of switchgear due to condensation under high humidity and pollution conditions, which may result in a switchgear insulation fault.
Shengwen Shu+5 more
semanticscholar +1 more source
2022 4th International Conference on Smart Power & Internet Energy Systems (SPIES), 2022
Moisture and condensation in high voltage switchgear will cause corrosion of parts, degradation of insulation performance and surface discharge.
Shen Genqiang+5 more
semanticscholar +1 more source
Moisture and condensation in high voltage switchgear will cause corrosion of parts, degradation of insulation performance and surface discharge.
Shen Genqiang+5 more
semanticscholar +1 more source
IEEE Electrical Insulation Magazine, 2021
In this article, switchgear standards, failure statistics, and condition assessment methods with a special focus on medium and high voltage classes are critically reviewed.
A. Subramaniam+4 more
semanticscholar +1 more source
In this article, switchgear standards, failure statistics, and condition assessment methods with a special focus on medium and high voltage classes are critically reviewed.
A. Subramaniam+4 more
semanticscholar +1 more source
Journal of the Institution of Electrical Engineers - Part I: General, 1948
This paper forms one of a series on standardization initiated by The Institution, and deals with switchgear for alternating-current systems.A wide diversity of requirements and many types and arrangements of switchgear available are reviewed from the aspect of standardization under four main sections: supply-system requirements; performance ...
J. Christie, D.E. Lambert
openaire +2 more sources
This paper forms one of a series on standardization initiated by The Institution, and deals with switchgear for alternating-current systems.A wide diversity of requirements and many types and arrangements of switchgear available are reviewed from the aspect of standardization under four main sections: supply-system requirements; performance ...
J. Christie, D.E. Lambert
openaire +2 more sources
Thermal simulation of switchgear
Proceedings of the Forth-Seventh IEEE Holm Conference on Electrical Contacts (IEEE Cat. No.01CH37192), 2002In development of low voltage switchgear, proper thermal design becomes more and more important to provide safe function and reliability in spite of miniaturization and increasing performance demanded of modern devices. Due to the high complexity of heat generation and loss processes it is not easy to predict the thermal behavior of devices under ...
P. Steinhaeuser+2 more
openaire +2 more sources
IEEE Sensors Journal, 2021
As a kind of widely used switchgear in power system, the reliability of gas insulated switchgear (GIS) is very important for the safe operation of power systems. However, there is a lack of research on intelligent detection technology of mechanical state
Yang Yuan+5 more
semanticscholar +1 more source
As a kind of widely used switchgear in power system, the reliability of gas insulated switchgear (GIS) is very important for the safe operation of power systems. However, there is a lack of research on intelligent detection technology of mechanical state
Yang Yuan+5 more
semanticscholar +1 more source