The manuscript presents advanced coupled analysis: Maxwell 3D, Transient Thermal and Fluent CFD, at the time of a rated current occurring on the main busbars in the low-voltage switchgear.
Michał Szulborski +2 more
doaj +2 more sources
Partial discharge defect recognition method of switchgear based on cloud-edge collaborative deep learning [PDF]
To address the limitations of traditional partial discharge (PD) detection methods for switchgear, which fail to meet the requirements for real-time monitoring, rapid assessment, sample fusion, and joint analysis in practical applications, a joint PD ...
Zhijie Jia +4 more
doaj +2 more sources
Diagnosis of Partial Discharge Based on the Air Components for the 10 kV Air-Insulated Switchgear. [PDF]
Partial discharge (PD) is a common phenomenon of insulation aging in air-insulated switchgear and will change the gas composition in the equipment. However, it is still a challenge to diagnose and identify the defect types of PD.
Tan Q, Zhang T, Wu S, Gao J, Song B.
europepmc +2 more sources
The development of renewable energies and smart mobility has profoundly impacted the future of the distribution grid. An increasing bidirectional energy flow stresses the assets of the distribution grid, especially medium voltage switchgear.
Martin W. Hoffmann +16 more
doaj +2 more sources
The explosion accident due to the internal arc fault in the metal‐enclosed switchgear cannot be ignored. Therefore, improving the ability of switchgear to resist the arc fault has important significance.
Peng Li +5 more
doaj +2 more sources
A Real-Time IR-Fusion Switchgear Contact Monitoring System (SCMS)
In this paper, a real-time monitoring system for switchgear contacts (switchgear contact monitoring system) with continuous thermal monitoring is presented instead of infrequent scanning with a handheld infrared (IR) camera or IR window.
Yunfeng Yan, Donglian Qi, Hong Gu
doaj +2 more sources
Finite Element Analysis and Experimental Study of Metal Shell of GIL [PDF]
Mathematical modeling, finite element numerical simulation and experimental measurement of the stress-deformation distribution of the gas-insulated metal-enclosed transmission line shell were carried out.
Mimi Gong +9 more
doaj +1 more source
In this paper, a bidirectional fluid–solid interaction method is established to investigate the influence of the outlet elastic baffle on the pressure in the arc chamber in the breaking process of a low-voltage circuit breaker. Based on the computational
Nairui Yin +3 more
doaj +1 more source
To void breakdown between busbars, the dissociation unit is applied in the arc chamber of an air circuit breaker (ACB) to cool down the hot gas exhausted from the vent of the arc chamber in the interrupting process. Cooling efficiency and flow resistance
Nairui Yin +3 more
doaj +1 more source
Due to the problems such as fuzzy state assessment grading boundaries, the recognition accuracy is low when using traditional fuzzy techniques to grade the switchgear state.
Xiaolong Xiao +10 more