Results 101 to 110 of about 1,432 (200)
For the study of transient overvoltage (TOV) in an offshore wind farm (OWF) collector system caused by switching off vacuum circuit breakers (VCBs), a simplified experimental platform of OWF medium-voltage (MV) cable collector system was established in ...
Honglei Deng +7 more
core +1 more source
Research on Transient Process of Electric Locomotive Auto-passing Neutral Section with Load
To theoretically analyze the overvoltage and overcurrent when the train runs through neutral section under traction condition and regeneration condition, the equivalent electrical circuit was developed based on T equivalent circuit of transformer.
Liu Ling, Xiong Chenglin
doaj
To address the challenges of system failures and equipment damage caused by excitation inrush currents and overvoltages during no-load energization of high-speed locomotive transformers, a simulation model was developed utilizing PSCAD electromagnetic ...
Junting Yan +3 more
doaj +1 more source
:In order to investigate the inhibition effect of prior rejuvenation on the initiation of electrical tree and the propagation of the tree in the cross-linked polyethylene cable under combined AC voltage and switching overvoltage,the prior rejuvenation ...
周凯 +5 more
doaj
A Review of Overvoltage Protection Technologies and Protective Devices for Wind Turbines
Wind turbines are persistently threatened by both lightning overvoltage and switching overvoltage due to their ultra-high structure, dense power electronics, and harsh operational environments, which severely endanger the safe and stable operation of the
Jinru Sun +7 more
doaj +1 more source
Large transient overvoltages can be caused by the switching operation of vacuum circuit breakers of induction motors. In order to analyze the switching transient overvoltage and use an appropriate protective method in the power system of floating ...
Xue, H. (author)
core
A substation is one of the essential aspects of an electrically interconnected system, especially in a grid utility. Power generation, transmission, and distribution systems always need a continuous power supply to the customer.
Bagus Irawan Saputra +2 more
doaj +1 more source
Research on the impact of transformer switching-off on core residual magnetism
Magnetizing inrush current caused by transformer no-load switching can lead to various issues in power grid operations. Techniques such as phase-controlled switching are effective in mitigating these effects, with the key factor being the measurement of ...
HAN Xiao +4 more
doaj +1 more source
Evaluation of the efficacy of transient overvoltages suppression measures in different wind farm topologies using SF6 circuit breaker. [PDF]
Eliyan T, Wadie F.
europepmc +1 more source
An advanced transient protection circuit for enhancing the overvoltage tolerance of MMC submodules
IGBTs are critical switching devices in MMCs, yet their vulnerability to turn-off overvoltage under transient and fault conditions poses a fundamental reliability challenge.
Chao You, Jiancheng Ma, Xin Chen
doaj +1 more source