Results 281 to 290 of about 3,558,385 (316)
Some of the next articles are maybe not open access.
IEEE transactions on power electronics
Grid-forming (GFM) converters with the widely adopted power-synchronization controller (PSC) are exposed to the risk of losing synchronization, due to their limited power transfer capability under severe symmetrical faults.
Shan Jiang +3 more
semanticscholar +1 more source
Grid-forming (GFM) converters with the widely adopted power-synchronization controller (PSC) are exposed to the risk of losing synchronization, due to their limited power transfer capability under severe symmetrical faults.
Shan Jiang +3 more
semanticscholar +1 more source
IEEE transactions on energy conversion
With the increasing penetration of voltage source converters (VSC) in the modern power grid, the transient stability of grid-following converters has attracted extensive attention.
Chao Wu +3 more
semanticscholar +1 more source
With the increasing penetration of voltage source converters (VSC) in the modern power grid, the transient stability of grid-following converters has attracted extensive attention.
Chao Wu +3 more
semanticscholar +1 more source
IEEE transactions on power electronics, 2022
Under grid fault, the grid-connected voltage source converters (VSCs) have the risk of transient synchronization instability during low voltage ride through.
Sen Huang +5 more
semanticscholar +1 more source
Under grid fault, the grid-connected voltage source converters (VSCs) have the risk of transient synchronization instability during low voltage ride through.
Sen Huang +5 more
semanticscholar +1 more source
IEEE transactions on industry applications
Affected by the current limitation, the operation of grid-forming (GFM) voltage source converters (VSCs) will be switched from a voltage source mode to a current source mode under grid faults.
Yushuang Liu +3 more
semanticscholar +1 more source
Affected by the current limitation, the operation of grid-forming (GFM) voltage source converters (VSCs) will be switched from a voltage source mode to a current source mode under grid faults.
Yushuang Liu +3 more
semanticscholar +1 more source
IEEE transactions on power electronics, 2022
Wind turbines (WTs) are prone to lose the synchronization during severe grid faults due to the absence of equilibrium point. To cope with the issue, this letter proposes a power compensation control for doubly fed induction generator based WT to enhance ...
Yihang Yang +4 more
semanticscholar +1 more source
Wind turbines (WTs) are prone to lose the synchronization during severe grid faults due to the absence of equilibrium point. To cope with the issue, this letter proposes a power compensation control for doubly fed induction generator based WT to enhance ...
Yihang Yang +4 more
semanticscholar +1 more source
Synchronization Stability Analysis Under Ultra-Weak Grid Considering Reactive Current Dynamics
IEEE transactions on industrial electronics (1982. Print)The synchronization stability of grid-following converter has attracted extensive attention. It has been reported that the transient synchronization behavior during a grid fault is dominated by the phase-locked loop (PLL), while the current loop is ...
Bin Hu +5 more
semanticscholar +1 more source
PLL Synchronization Stability of Grid-Connected VSCs Under Asymmetric AC Faults
IEEE transactions on energy conversion, 2022This paper investigates the phase-locked loop (PLL) synchronization stability of grid-connected voltage source converters (VSCs) under asymmetric ac faults.
Yingbiao Li +3 more
semanticscholar +1 more source
Equivalent Aggregated Modeling of Multi-VSC System for Transient Synchronization Stability Analysis
IEEE Transactions on Power SystemsIn a multi-voltage-source-converter (multi-VSC) system, there may be a scenario where some VSCs lose synchronization stability and others keep stable under grid faults.
Yushuang Liu +5 more
semanticscholar +1 more source
Impact of DC-Bus Voltage Control on Synchronization Stability of Grid-Tied Inverters
IEEE Transactions on Circuits and Systems - II - Express Briefs, 2022The impact of dc-bus voltage control (DVC) on transient synchronization stability of grid-tied inverters operating in grid-feeding mode has been assessed in this brief. A nonlinear quasi-static model magnifying the dynamics of phase-locked loop (PLL) and
Diptak Pal, B. K. Panigrahi
semanticscholar +1 more source
Transient Synchronization Stability Analysis of a Grid-Connected Wind Farm With Multiple PMSGs
IEEE Transactions on Power SystemsThe paper proposes an analytical examination of the transient synchronization stability (TSS) of a grid-connected wind farm with multiple permanent magnet synchronous generators (PMSGs).
Zhen Gao +5 more
semanticscholar +1 more source

