Results 31 to 40 of about 9,115 (324)

LCC-HVDC Converter Station Reactive Power Optimization and Two-Layer Coordination Strategy Research Based on Synchronous Sondenser

open access: yes南方能源建设, 2023
[Introduction] Under the existing converter station reactive power compensation scheme, the synchronous condenser only provides transient reactive power support, and the AC (Alternating Current) filter undertakes steady-state reactive power compensation ...
Dongqing ZHANG   +3 more
doaj   +1 more source

Parameter setting method of coordinated control between synchronous condenser and DC system based on dynamic reactive power optimization

open access: yesIET Generation, Transmission & Distribution, 2022
It is of great significance for improving the safety and stability of the system to realize the coordinated and optimal control between synchronous condenser and DC system in UHVDC converter station.
Jingshan Mo   +3 more
doaj   +1 more source

Inertia compensation of power grid with flywheel-integrated synchronous condenser

open access: yesAIMS Energy, 2023
This paper studies the integration of flywheel energy storage system (FESS) to a synchronous condenser (SC) and its effect on the stability margin of the power system.
Parveen Tania   +2 more
doaj   +1 more source

Suppressing Effect of Synchronous Condenser on Transient Overvoltage of UHVDC System under Hierarchical Connection Mode

open access: yesZhongguo dianli, 2020
At present, hierarchical connection mode has been adopted in UHVDC projects, and with the increasing proportion of new energy generation, the power grid at the sending end is facing the problem of transient overvoltage (TOV), which can be restrained by ...
Li QIAO, Hang WANG, Jian XIE, Chunyi GUO
doaj   +1 more source

Setting Configuration and Adjustment Method of Synchronous Condenser System Under Idling Conditions

open access: yesZhongguo dianli, 2023
When connecting the idling condenser to the grid, it is difficult to configure the setting value of the synchronization system to balance the requirements of grid connection success rate and current shock together. In this paper the idling characteristic
Jiyin SHI   +4 more
doaj   +1 more source

Operating Point Optimization of a Hydrogen Fueled Hybrid Solid Oxide Fuel Cell-Steam Turbine (SOFC-ST) Plant [PDF]

open access: yes, 2013
This paper presents a hydrogen powered hybrid solid oxide fuel cell-steam turbine (SOFC-ST) system and studies its optimal operating conditions. This type of installation can be very appropriate to complement the intermittent generation of renewable ...
Ostolaza Zamora, Joseba Xabier   +2 more
core   +2 more sources

Nonsynchronous Rotor Blade Vibrations in Last Stage of 380 MW LP Steam Turbine at Various Condenser Pressures

open access: yesApplied Sciences, 2022
This paper presents an analysis of nonsynchronous rotor blade vibrations in the last stage of an LP steam turbine at various condenser pressures. The nonlinear least squares Levenberg–Marquardt method is used in a tip-timing analysis to determine ...
Romuald Rzadkowski   +4 more
doaj   +1 more source

Multi-terminal HVDC grids with inertia mimicry capability [PDF]

open access: yes, 2016
The high-voltage multi-terminal dc (MTDC) systems are foreseen to experience an important development in the next years. Currently, they have appeared to be a prevailing technical and economical solution for harvesting offshore wind energy. In this study,
Gharehpetian, Gevorg B.   +4 more
core   +2 more sources

Improving Grid-Connection Reliability and Safety of Synchronous Condensers With Start-Up Process Optimization

open access: yesIEEE Access, 2020
The new-type synchronous condenser uses the uncontrollable and irreversible freewheeling grid-connection mode during the start-up process, so that considerable rates of grid-connection failure could be observed in case of strict grid-connection ...
Yichao Sun   +3 more
doaj   +1 more source

High Voltage Ride through Strategy of Wind Farm Considering Generator Terminal Voltage Distribution

open access: yesApplied Sciences, 2021
When wind power is transmitted via high-voltage direct current (HVDC), the problem of high-voltage ride-through (HVRT), caused by direct-current (DC) blocking must be seriously taken into account.
Yanhui Qin   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy