Machine learning algorithms for voltage stability assessment in electrical distribution systems. [PDF]
Mossie MA +4 more
europepmc +1 more source
Smart Sensors and Standard-Based Interoperability in Smart Grids. [PDF]
Song EY, FitzPatrick GJ, Lee KB.
europepmc +1 more source
Wide-area measurement system-based supervision of protection schemes with minimum number of phasor measurement units. [PDF]
Gajare S +4 more
europepmc +1 more source
Capabilities of battery and compressed air storage in the economic energy scheduling and flexibility regulation of multi-microgrids including non-renewable/renewable units. [PDF]
Naghibi AF +4 more
europepmc +1 more source
Optimized CNN-BiLSTM framework for reactive power management and voltage profile improvement in renewable energy based power grids. [PDF]
Varghese LJ +3 more
europepmc +1 more source
An adaptive load shedding methodology for renewable integrated power systems. [PDF]
Abrar SF, Masood NA, Alam MJ.
europepmc +1 more source
Related searches:
Synchronized phasor measurements provide the basis for fine-grained wide area power quality monitoring in electric grids. Time-synchronized phasor measurement units (PMUs) are deployed at different locations in the grid and report 10–60 measurements/second to energy management systems or other applications.
Tanja Zseby, Joachim Fabini, Dipika Rani
openaire +1 more source
Advanced synchrophasor applications
IEEE PES General Meeting, 2010GPS synchronized measurements are becoming common and there is tremendous activity to develop applications and utilize these measurements. While, presently the applications lag the hardware developments, there is a great activity towards development of a variety of applications and utilization of GPS synchronized data.
A P Sakis Meliopoulos +1 more
openaire +1 more source
Synchrophasor-Assisted Zone 3 Operation
IEEE Transactions on Power Delivery, 2014Zone 3 operation of distance relay serves as a remote backup in case of primary failure. Conditions, such as power swing, load encroachment, and voltage and transient instability, cause incorrect zone 3 operation. The detection of faults during such stressed conditions poses a further problem.
Pratim Kundu, Ashok Pradhan
openaire +1 more source
Synchrophasor data availability analyzer
2016 International Conference on Probabilistic Methods Applied to Power Systems (PMAPS), 2016Wide-area monitoring system (WAMS) is emerging technologies that utilize phasor measurement units (PMUs) combined with highly accurate time synchronization to deliver the time-synchronized phasor data known as “synchrophasor”. To enable more extensive applications from WAMS, an excellent synchrophasor data availability level is a must-have.
Phanuwat Phunkasem +3 more
openaire +1 more source

