Results 51 to 60 of about 154 (146)
Signal selection and latency compensation in wide area controlled power system
Abstract This paper presents a new approach for selecting signals for the monitoring and control of power systems over a wide area. The approach solves the twin problems of locating Phasor Measurement Units for observability and placing dynamic controllers for controllability using distinct techniques.
Prakash Thyagarajan +1 more
wiley +1 more source
Audur—A platform for synchrophasor-based power system wide-area control system implementation
Electrical power systems continue to grow in size and complexity, resulting in new challenges to control and stabilize them. Measurement based Wide-Area Control Systems (WACS) have been extensively researched in the last decade to enhance power system ...
L. Vanfretti +5 more
doaj +1 more source
Power system inter-area oscillations curtail the power transferring capabilities of the transmission lines in a large interconnected power system. Accurate identification of dominant modes and associated contributing generators is important to avoid ...
Mohd Zuhaib, Mohd Rihan
doaj +1 more source
Static VAr Compensators can provide significant improvement in power system stability. Phasor Measurement Units are used in combination with SVCs for fast and reliable control of its operation. By combining the VAr control and Voltage Regulation control methods of the SVC, superior performance is obtained.
Faris Alsalem, Ayman Faza
wiley +1 more source
In recent years, machine learning (ML) techniques have gained popularity in facilitating real‐time transient stability assessment and prediction for early detection of blackouts in power systems.
Tohid Behdadnia +2 more
doaj +1 more source
Securing Synchrophasors Using Data Provenance in the Quantum Era
Trust in the fidelity of synchrophasor measurements is crucial for the correct operation of modern power grids. While most of the existing research on data provenance focuses on the Internet of Things, there is a significant need for effective malicious ...
Kashif Javed +4 more
doaj +1 more source
Data‐Driven Anomaly Detection and Mitigation for FACTS‐Based Wide‐Area Voltage Control System
Figure 4 presents the schematic diagram of data‐driven attack‐resilient system for the wide‐area voltage controller that seamlessly integrates machine learning‐based anomaly detector with rules‐based attack mitigation system while supporting the normal operation of WAVCS in real‐time.
Vivek Kumar Singh +2 more
wiley +1 more source
A Hybrid Synchrophasor and GOOSE-Based Power System Synchronization Scheme
The design and real-time hardware-in-the-loop implementation of a hybrid synchrophasors and GOOSE-based automatic synchronization algorithm are presented in this paper.
Muhammad Shoaib Almas, Luigi Vanfretti
doaj +1 more source
In modern power systems, phasor measurements are expected to deal with challenging conditions, e.g., fast dynamics and high distortion levels. Taylor-Fourier Multifrequency models represent a promising solution, but their performance is strongly related ...
Guglielmo Frigo +2 more
doaj +1 more source
The technique involves source authentication to detect anomalies in phasor measurement unit (PMU) data by extracting spatial fingerprint information. The extracted information is then used as inputs for a multi‐dimensional convolutional neural network simulation framework.
Robert Nobili Britto Thomas +3 more
wiley +1 more source

