In vitroevaluation of T-Scan®III through study of the sensels

CRANIO®, 2015
To evaluate the validity and reliability of the T-Scan®III sensors system by measuring force and time in sensels.In order to evaluate the validity, known forces were applied to 31 sensels selected at random of a T-Scan® III sensor. In order to evaluate the reliability, the existing agreement between two different sensors was measured. Both validity and
Manuel, Cerna   +4 more
openaire   +2 more sources

Occlusal control of implant supported prothesis with T-scan - III system

Clinical oral implants research, 2012
Background: The occlusal forces applied to an implant sup- ported prosthesis can be a potentially destructed factor in shortening the functional durability of this reconstructions. Aim: The aim of this study was to compare the occlusal load of natural tooth on one side, and implant supported crowns and bridges on the other side of the jaw.
Živko-Babić, Jasenka   +2 more
openaire   +2 more sources

Precision and Reliability of the T-Scan III System

2015
Precise analysis of occlusal contacts and occlusal force is a problem in functional diagnostics that has not yet been satisfactorily resolved, despite the fact that the deleterious consequences of an unbalanced occlusion are widespread and can be severe.
openaire   +1 more source

Validity and reliability of the T‐Scan®III for measuring force under laboratory conditions

Journal of Oral Rehabilitation, 2015
SummaryAlthough measuring bite force is an important indicator of the health of the masticatory system, few commercially available transducers have been validated for routine clinical use. T‐Scan®III Occlusal Analysis System allows to record the bite force distribution, indicating its relative intensity and occlusal timing.
M, Cerna   +4 more
openaire   +2 more sources

Adjustment of Occlusal Splint with Synchronized T-Scan III Digital Occlusal Analysis System and Bio-EMG III in a Patient with Sleep Bruxism

Journal of Advanced Oral Research, 2020
The occlusal splint has been frequently used as an effective treatment in sleep bruxism patients. In the adjustment procedure of occlusal splint with an optimal occlusion, clinicians usually use conventional methods; however, they cannot measure the surface area of contacts, amount of force, and contacting time sequence.
Karakış, Duygu, Demirdag, Elif Didem
openaire   +2 more sources

[Normal occlusion study: using T-Scan III occlusal analysis system].

Zhonghua kou qiang yi xue za zhi = Zhonghua kouqiang yixue zazhi = Chinese journal of stomatology, 2014
To investigate the normal occlusal force distribution and the characteristics of the occlusion time at different occlusion position using T-Scan III occlusal analysis system.Fifty-three volunteers with normal occlusion, including 29 males and 24 females, were included in this study. The average age was (25.9 ± 2.1) years old.
Fei-fei, Ma   +3 more
openaire   +1 more source