Optometry and Vision Science, 1992
The measurement of tear break-up time (TBUT) in assessing stability of the tear film is somewhat controversial, even though the technique is widely used. We examined reliability of the technique within and among examiners and conclude that measurements of TBUT can be made reliably; full-beam observation of the cornea is preferable to scanning the ...
P, Cho +4 more
openaire +2 more sources
The measurement of tear break-up time (TBUT) in assessing stability of the tear film is somewhat controversial, even though the technique is widely used. We examined reliability of the technique within and among examiners and conclude that measurements of TBUT can be made reliably; full-beam observation of the cornea is preferable to scanning the ...
P, Cho +4 more
openaire +2 more sources
The non-invasive tear film break-up time in normal children
British Journal of Ophthalmology, 2013To perform an objective evaluation of the non-invasive tear break-up time (NITBUT) and lipid layer interferometry in normal children.Children with no known ocular surface disease or anterior segment abnormality were evaluated. We excluded patients with disorders affecting lid margins or tear film composition.
Sophie M, Jones, Ken K, Nischal
openaire +2 more sources
Tear Film Break-up Time Evaluated by Real-Time Hartmann-Shack Wavefront Sensing
Japanese Journal of Ophthalmology, 2006To develop a novel method for measuring tear break-up time (BUT) by continuously measuring higher order wavefront aberrations using a Hartmann-Shack (H-S) aberrometer.Wavefront aberrations up to the sixth order for a 4-mm pupil were measured in six eyes of six normal subjects using an H-S aberrometer. The aberrometry was performed once every second for
Toshifumi Mihashi +5 more
openaire +2 more sources
Thermographic evaluation of tear film break-up time to study tear film stability
International Journal of Thermal Sciences, 2016Abstract Tear film instability is one of the major characteristics of dry eye syndrome. However, traditional diagnostic method like fluorescein tear film break-up time (FTBUT) test is limited by its invasiveness, the necessity to use fluorescein sodium and thus variable result.
Tai Yuan Su +3 more
openaire +1 more source
Capsaicin-induced pain sensitivity in short tear break-up time dry eye
The Ocular Surface, 2020To evaluate transient receptor potential vanilloid 1 (TRPV1)-mediated pain sensitivity in patients with short tear break-up time (TBUT) dry eye (DE) by using the capsaicin stimulus test.This prospective cross-sectional comparative study included 22 eyes of 22 patients with short TBUT DE and 11 eyes of 11 non-DE control subjects.
Minako Kaido +5 more
openaire +2 more sources
Non invasive tear film break‐up time and blinking
Acta Ophthalmologica, 2012AbstractPurpose The break‐up time of the tear film for evaluation of dry eyes is performed with fluorescein in blue light of the slit lamp. Errors may occure by the observer and has to be repeated for accurat results. The BUT can also be seen with a Keratograph 4 (KG‐BUT). In this pilot‐study we want to evaluate the measurements with KG‐BUT in patients
openaire +1 more source
Tear break-up time among menopausal women
Journal of Health and Visual Sciences, 2010No Abstract.
Osude-Uzodike, ED, Anachebe, CG
openaire +1 more source
[Tear film break-up time with different stains].
Klinische Monatsblatter fur Augenheilkunde, 1983The tear film break-up time is usually measured with the lacrimal fluid stained with fluorescein. With the staining methods currently recommended the break-up time is difficult to reproduce. In the study described here, the break-up times with different staining methods were compared.
R, Stodtmeister +2 more
openaire +1 more source
The effect of tear substitutes on tear film break-up time.
Investigative ophthalmology, 1975Twelve commercial artificial tear solutions and a newly developed one were evaluated as to their effect on tear film breakup time (BUT) in ten normal subjects. Instillation of one drop of these solutions altered the BUT in such a way that serial BUT measurements could be used as an index of retention time.
M A, Lemp, M, Goldberg, M R, Roddy
openaire +1 more source
Study of tear film flow and break up time (BUT) in trachoma
Acta Ophthalmologica, 1986Abstract Tear film flow and stability studies were carried out in patients suffering from cicatrizing trachoma by Schirmer test I and tear film break‐up‐time (BUT) measurements, respectively. Both Schirmer test I and BUT values were decreased significantly (t‐test, P < 0.001) depicting aqueous as well as mucin deficiency and hence, an unstable tear ...
S S, Moudgil +3 more
openaire +2 more sources