Results 31 to 40 of about 241,804 (118)
CLINICAL COMPARISON OF TECHNETIUM-99M-EC, TECHNETIUM-99M-MAG3 AND IODINE-131-OIH IN RENAL DISORDERS
Technetium-99m-ethylenedicysteine has recently been developed for renal function studies. The pharmacokinetics of Tc-99m-EC were studied by constant infusion technique and compared with Tc-99m-MAG3 and I-131-OIH in, 11 patients with various renal ...
TUROGLU, HT +11 more
core +1 more source
: The aims of this study were: (a) to define the accuracy of a preoperative parathyroid imaging protocol based on the combination of technetium-99m pertechnetate/technetium-99m methoxyisobutylisonitrile ((TcO4)-Tc-99m/Tc-99m-MIBI) scan and neck ...
PELIZZO, MARIA ROSA +3 more
core +1 more source
PubMedID: 12846544Technetium-99m dimercaptosuccinic acid (Tc-99m DMSA) as a static renal agent is currently the most frequently used agent in the detection of renal scarring, and allows accurate calculation of differential renal function (DRF).
Kibar M., Yapar Z., Noyan A., Anarat A.
core +1 more source
TECHNETIUM-99M PYROPHOSPHATE IMAGING IN ACUTE MYOCARDIAL-INFARCTION - COMPARISON OF PLANAR IMAGES WITH SUPERIMPOSITION ...
M LEWIS (15917450) +8 more
core +1 more source
Technetium-99m ethylene dicysteine: a new renal tubular function agent
Technetium-99m ethylene dicysteine (EC), a metabolite of ethylene cysteine dimer (ECD), is a new technetium-labelled renal tubular function tracer introduced as an alternative to ortho-iodohippurate (OIH) and with imaging qualities similar to Tc-99m ...
Kabasakal, L
core +1 more source
Technetium-99m-labeled N,N-ethylenedicysteine (Tc-99m-EC) is a new renal imaging agent introduced as an alternative for Tc-99m-labeled mercaptoacetyltriglycine (Tc-99m-MAG3), with similar renal excretion characteristics.
CANSIZ, T +8 more
core +1 more source
Mean opacity and mean Tc-99m-MDP activity.
The figure represents the mean opacity (above) and the mean Tc-99m-MDP activity (below) of PMMA (blue) and HLBC (orange) at third weeks (A, C) and at eight weeks after surgery (B, D).
Ferenc Budán (3522674) +9 more
core +1 more source
Thirty one female patients(age range 23~71 years) with suspicious breast lesions underwent technetium-99m methoxyisobutylisonitrile(Tc-99m MIBI) breast scintigraphy in order to assess the value of this technique in the detection of breast carcinomas and ...
박, 찬희 +4 more
core +1 more source
Technetium-99m nitride radiopharmaceuticals
Following the introduction of an efficient method for the preparation of technetium-99m complexes containing a terminal Tc≡N multiple bond, under conditions suitable for nuclear medicine applications, new radio-pharmaceuticals for heart and brain imaging
UCCELLI, Licia +3 more
core +1 more source
An assessment study involving the use of the transglutaminase (TGase) conjugation method and the nitride-technetium-99m labelling on a bis(thiosemicarbazone) (BTS) bifunctional chelating agent is presented. The previously described chelator diacetyl-2-(N-
Cicoria, Gianfranco +17 more
core +1 more source