Results 111 to 120 of about 7,037,660 (293)

Brain magnetic resonance imaging predictors in anti‐N‐methyl‐D‐aspartate receptor encephalitis

open access: yesAnnals of Clinical and Translational Neurology, Volume 9, Issue 12, Page 1974-1984, December 2022., 2022
Abstract Objective Brain magnetic resonance imaging (MRI) findings in anti‐N‐methyl‐D‐aspartate receptor (NMDAR) encephalitis are nonspecific and rarely have obvious associations with clinical characteristics and outcomes. This study aimed to comprehensively describe the MRI features of patients with NMDAR encephalitis, examine their associations with ...
Ying‐Ying Zhao   +8 more
wiley   +1 more source

Comparing the physical characteristics of ultrasound and magnetic resonance imaging to diagnose ovarian cysts [PDF]

open access: yesarXiv
Background, For the purpose of determining the appropriate course of therapy to maintain fertility, a correct diagnosis of ovarian cysts is crucial. Objective, To contrast the results of magnetic resonance imaging and ultrasonography in individuals with ovarian cysts .
arxiv  

Evaluation of the effect of metal stents on dose perturbation in the carbon beam irradiation field

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Propose Carbon ion therapy is indicated for cases in which stents have been inserted, such as bile ducts, but the effect of metal stents on carbon ion therapy is unclear. In this study, the dose perturbation of carbon ion therapy caused by metallic bile duct stents was evaluated by dosimetry. Materials and methods Five different types of metal
Yuya Miyasaka   +8 more
wiley   +1 more source

The anterior nucleus of the thalamus plays a role in the epileptic network

open access: yesAnnals of Clinical and Translational Neurology, Volume 9, Issue 12, Page 2010-2024, December 2022., 2022
Abstract Objectives We investigated both the metabolic differences and interictal/ictal discharges of the anterior nucleus of the thalamus (ANT) in patients with epilepsy to clarify the relationship between the ANT and the epileptic network. Methods Nineteen patients with drug‐resistant epilepsy who underwent stereoelectroencephalography were studied ...
Hao Yan   +9 more
wiley   +1 more source

Closing the gap in plan quality: Leveraging deep‐learning dose prediction for adaptive radiotherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Balancing quality and efficiency has been a challenge for online adaptive therapy. Most systems start the online re‐optimization with the original planning goals. While some systems allow planners to modify the planning goals, achieving a high‐quality plan within time constraints remains a common barrier.
Sean J. Domal   +9 more
wiley   +1 more source

Stereotactic radiotherapy for metastatic brain tumors: A comparative analysis of dose distributions among VMAT, Helical TomoTherapy, CyberKnife, Gamma Knife, and ZAP‐X

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract This study evaluates various radiotherapy techniques for treating metastatic brain tumor (BT), focusing on non‐coplanar volumetric modulated arc radiotherapy (NC‐VMAT), coplanar VMAT (C‐VMAT), Helical TomoTherapy (HT), CyberKnife (CK), Gamma Knife (GK), and ZAP‐X.
Toshihiro Suzuki   +9 more
wiley   +1 more source

Manuscript preparation guide for Radiological Physics and Technology [PDF]

open access: yesarXiv
This guide is intended for authors who wish to publish an original paper in Radiological Physics and Technology. They should follow the submission guidelines of the journal as well as standard guidelines and conventions for scientific writing. The journal recommends a standard structure for the main text and requires an additional section for ...
arxiv  

A comparative analysis of deep learning architectures with data augmentation and multichannel input for locoregional breast cancer radiotherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Studies on deep learning dose prediction increasingly focus on 3D models with multiple input channels and data augmentation, which increases the training time and thus also the environmental burden and hampers the ease of re‐training. Here we compare 2D and 3D U‐Net models with clinical accepted plans to evaluate the appropriateness of
Rosalie Klarenberg   +2 more
wiley   +1 more source

Statistical Analysis of Quantitative Cancer Imaging Data [PDF]

open access: yesarXiv
Recent advances in types and extent of medical imaging technologies has led to proliferation of multimodal quantitative imaging data in cancer. Quantitative medical imaging data refer to numerical representations derived from medical imaging technologies, such as radiology and pathology imaging, that can be used to assess and quantify characteristics ...
arxiv  

A Randomized Controlled Trial on 2 Simulation-Based Training Methods in Radiology: Effects on Radiologic Technology Student Skill in Assessing Image Quality

open access: yesSimulation in Healthcare: The Journal of the Society for Simulation in Healthcare, 2013
J. Ahlqvist   +8 more