Results 141 to 150 of about 2,072,263 (282)

In Situ Quantization with Memory‐Transistor Transfer Unit Based on Electrochemical Random‐Access Memory for Edge Applications

open access: yesAdvanced Science, EarlyView.
By combining ionic nonvolatile memories and transistors, this work proposes a compact synaptic unit to enable low‐precision neural network training. The design supports in situ weight quantization without extra programming and achieves accuracy comparable to ideal methods. This work obtains energy consumption advantage of 25.51× (ECRAM) and 4.84× (RRAM)
Zhen Yang   +9 more
wiley   +1 more source

Why the Government Should Not Regulate Internet Telephony? [PDF]

open access: yes
The Federal Communications Commission has requested comments on the regulation of voice telephone services delivered over the Internet, dubbed "VoIP" or Voice over Internet Protocol. This paper examines whether there is a need to regulate VoIP.
Crandall, Robert W.   +3 more
core   +1 more source

In‐Wheel Piezoelectric DC Power Generator With Zero Resistive Torque

open access: yesAdvanced Science, EarlyView.
In this paper, we present a wheel‐shaped direct‐current piezoelectric generator (DC‐PG) that fundamentally overcomes these constraints by producing phase‐stable DC electricity directly from rolling motion. By embedding this system into suitcase wheels, we demonstrated a fully integrated real‐time location tracking system powered solely by mechanical ...
Hyun Soo Kim   +19 more
wiley   +1 more source

A feasibility study of cell phone and landline phone interviews for monitoring of risk and protection factors for chronic diseases in Brazil

open access: yesCadernos de Saúde Pública
The study objective was to evaluate the feasibility of interviews by cell phone as a complement to interviews by landline to estimate risk and protection factors for chronic non-communicable diseases. Adult cell phone users were evaluated by random digit
Erly Catarina Moura   +5 more
doaj  

Achieving Photo‐Activated Circularly Polarized Room Temperature Phosphorescence from Natural Biopolymers

open access: yesAdvanced Science, EarlyView.
This bio‐based chiral luminescent system exhibit photo‐activated CPRTP by anchoring arylboronic acids to hydroxypropyl cellulose (HPC) matrix. Notably, by controlling the drying kinetics, dynamic switchable CPRTP with opposite handedness can be obtained due to a balance of photonic bandgap (PBG) effect and chirality transfer effect induced by the HPC ...
Shaoyi Cao   +12 more
wiley   +1 more source

Computer simulator for a mobile telephone system [PDF]

open access: yes
A software simulator to help NASA in the design of the LMSS was developed. The simulator will be used to study the characteristics of implementation requirements of the LMSS's configuration with specifications as outlined by ...
Schilling, D. L., Ziegler, C.
core   +1 more source

Bimodal Mechanoluminescence Enables Multicolor Luminescent Tailing for Ultra‐Accurate Loading Speed Visualization and Detection

open access: yesAdvanced Science, EarlyView.
MgF2 exhibits a speed‐dependent mechanoluminescence (ML) color distribution arising from distinct ML lifetimes, showing blue emission under slow sliding and multicolor emission under fast sliding. A promising method for evaluating ML lifetime is proposed based on the trailing effect. By synergistically integrating instantaneous and persistent ML with a
Shulong Chang   +8 more
wiley   +1 more source

Programming Next‐Generation Synthetic Biosensors by Genetic Circuit Design

open access: yesAdvanced Science, EarlyView.
Synthetic biology enables genetic circuit‐based biosensing to detect diverse targets, process signals, and transduce them into readable outputs or intracellular regulatory activities. However, field deployment and real‐world application of such synthetic biosensors face considerable challenges in sensitivity, specificity, speed, stability, and ...
Yuanli Gao   +4 more
wiley   +1 more source

A smart headband for multimodal physiological monitoring in human exercises

open access: yesAdvanced Science, EarlyView.
A novel smart headband incorporating a thermal‐sensation‐based electronic skin is presented for continuous and accurate multimodal physiological monitoring, including pulse waveforms, total metabolic energy expenditure, heart rate, and forehead temperature, across both static and dynamic daily activities.
Shiqiang Liu   +7 more
wiley   +1 more source

Liquid Metal Elastomer Based Coplanar Waveguide Transmission Line for Stretchable and Self‐Healing RF Electronics

open access: yesAdvanced Electronic Materials, EarlyView.
This work shows the first proof‐of‐concept for fully self‐healing and stretchable coplanar waveguide (CPW) transmission line using printable electrically conductive liquid metal elastomer. RF performance was evaluated in frequency ranging from 1 to 6 GHz under uniaxial tensile strain up to 100%, after self‐healing, and for 1000 cyclic stretch‐release ...
Ahmed Albeltagi   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy