Investigation and Mitigation of Temporary Overvoltage Caused by De-Energization on an Offshore Wind Farm

open access: yesEnergies, 2020
The Ferranti effect could cause a rise in voltage along the cables on a wind farm if the circuit breakers at the receiving ends are switched off. Ferroresonance could also occur due to stuck pole(s) of the circuit breaker during de-energization.
Ajibola Akinrinde   +2 more
doaj   +2 more sources

Optimizing Lightning Arrester Selection for 275kV EHV Substations: A Comparison of Overvoltage Analysis with Software and Manual Calculations

open access: yesJurnal Nasional Teknik Elektro
A substation is one of the essential aspects of an electrically interconnected system, especially in a grid utility. Power generation, transmission, and distribution systems always need a continuous power supply to the customer.
Bagus Irawan Saputra   +2 more
doaj   +3 more sources

Covered conductor burn-down prevention for distribution line in Indonesia

open access: yesMATEC Web of Conferences, 2018
Covered conductor (CC) is used to resolve temporary line to ground fault in the distribution line. However, some cases of CC burn down were found in Indonesia.
Pramana Putu Agus Aditya   +3 more
doaj   +3 more sources

Transient analysis of temporary overvoltage and cable faults in underground medium voltage systems

open access: yesResults in Engineering
This paper evaluates the challenges faced by renewable power plants in 2024 concerning underground cables designed according to industry standards. It emphasizes the need for optimization in cable operation to enhance efficiency and power throughput ...
Ricardo Manuel Arias Velásquez
doaj   +2 more sources

Temporary overvoltage duty of surge arresters in noneffectively grounded systems

open access: yesElectrical Engineering in Japan, 1997
Important characteristics of metal oxide surge arresters depend on the specified temporary overvoltage duty requirement due to the volt–ampere characteristics. However, there are few reports on the duty of surge arresters in noneffectively grounded systems.
Kouiti Nakahito   +7 more
openaire   +3 more sources

Control of Valve Converters with Natural Current Characteristics [PDF]

open access: yesMATEC Web of Conferences, 2018
The article considers the valve converter with a natural current characteristic, which is called the current of parametric, for which the primary is not the source of the electric force but a parametric source of current, to the output of which connected
Mendybayev Sergazy   +2 more
doaj   +2 more sources

Development Of Algorithms For Measuring Nonsinusoidality Voltage And Temporary Overvoltage [PDF]

open access: yes, 2021
Today, operating electrical networks, low and high voltage devices, and engines cause incidents that are characterized by the deviation of parameters from the nominal values. Yet, due to switching of the load cause temporary overvoltages. Besides, emergency modes caused by power outages and sudden failure of equipment of consumers, additionally cause ...
Nikonov, M., Kramskyi, I.
openaire   +2 more sources

Metal Oxide Surge Arresters Modelling in Temporary Overvoltage Conditions

open access: yesInternational Journal of Electronics and Electrical Engineering, 2016
Wichet Thipprasert, Ekkachai Chaidee
openaire   +2 more sources

Investigation and mitigation of temporary overvoltage caused by harmonic filters for variable speed drives

open access: yes, 2021
A dissertation submitted in fulfilment of the requirements for the Master of Engineering Degree in the Department of Electrical Power Engineering, Faculty of Engineering and the Built Environment, Durban University of Technology, 2021.The introduction of
Ayar, Prenushka
core   +1 more source

A Review of Current-Limiting Control of Grid-Forming Inverters Under Symmetrical Disturbances

open access: yesIEEE Open Journal of Power Electronics, 2022
Grid-forming (GFM) inverters are recognized as a viable solution to increase the penetration of renewable energy in bulk power systems. However, they are physically different from synchronous generators in terms of overcurrent capability.
Bo Fan   +4 more
doaj   +1 more source