Results 61 to 70 of about 329 (178)
Study of Temporary Overvoltages in 110/13.8/6.6 Kv Power Substation
Over voltages, be it of any magnitude, shape or amplitude adversely affect the smooth working of power substation and may prove to be fatal in many cases. In this paper study of insulation coordination of temporary over voltages (TOV) has been carried out in 110/13.8/6.6 kV substations.
Ishta Garg +2 more
openaire +1 more source
473480Temporary overvoltages in transmission and distribution systems can cause power outages due to disconnection of Power Generation Modules (PGMs), which could ultimately jeopardize the stability of the grid.
Ayadi, Yacine +5 more
core +1 more source
Measuring line design for temporary overvoltage measurements
Namen magistrske naloge je sestava koncepta merilne proge za izvajanje določenih testov po standardu za prenapetostne zaščite v nizkonapetostnih elektroenergetskih inštalacijah.
ZUPANČIČ, ROK
core
Electrical withstand performance of Malaysian based palm oil under influence of HVDC stress
Overvoltage is a phenomenon where electrical waveform applied to circuit or device exceeds normal operating parameters. The sources of overvoltage are often unpredictable and can lead to permanent degradation, failure or temporary malfunction of devices ...
Haliap, Mohd Kharul Anuar +5 more
core
Evaluation of the efficacy of transient overvoltages suppression measures in different wind farm topologies using SF6 circuit breaker. [PDF]
Eliyan T, Wadie F.
europepmc +1 more source
Overvoltage protection of high voltage ac power cables
Načinjen je pregled najviše korištenih konstrukcija visokonaponskih podzemnih kabela, karakterističnih izvedbi kabelskih vodova, načina uzemljivanja zaslona kabela i pregled Cigré-ovih statistika podzemnih kabela. Opisan je postupak provedbe koordinacije
Dropulić, Toni
core
Energy Stress of Surge Arresters Due to Temporary Overvoltages
The paper presents a method for selecting the rated voltage of a metal oxide surge arresters (MOSA) based on the calculation of energy stresses. The electrical behaviour of gapless MOSA under temporary overvoltages (TOV) is important when selecting the rated voltage of MOSA.
Filipović-Grčić, Božidar +4 more
openaire +3 more sources
Strategy for Optimal Grid Planning and System Evaluation of Networked Distribution Systems
The meshed network may become a standard for future distribution systems owing to its various benefits regarding voltage profile, reliability, losses, and the distributed generation (DG). Therefore, in Korea, there is a plan to introduce an advanced form
Myungseok Yoon +4 more
core +1 more source
The power-frequency withstand voltage tests are regulated on electric power equipment in JEC by evaluating the lifetime reliability with a Weibull distribution function. The evaluation method is still controversial in terms of consideration of a plural number of faults and some alternative methods were proposed on this subject.
Okabe, Shigemitsu +2 more
openaire +2 more sources
The concept of a new two-stage fuse for high power pulse forming. [PDF]
Nowak M.
europepmc +1 more source