Results 101 to 110 of about 3,990 (185)

A Power-Factor-Corrected Wireless Charging System with Simple Control for Indoor Mobile Robots

open access: yesEnergies
A conventional resonant-inductive wireless charging system includes a power factor corrector (PFC) to maintain a high input power factor (PF) and low distortion of the input current (THDI).
Deniss Stepins   +5 more
doaj   +1 more source

Damping Harmonic Distortion Using Active Filter with PID Control at Udayana University Faculty of Engineering Bukit Jimbaran

open access: yesJournal of Electrical, Electronics and Informatics, 2018
Increased THD (Total Harmonics Distortion) in the utility, caused by the increasing operation of non-linear loads. High THD current (THDi) will affect the increase of power losses in the power system. In this study, THD analysis of the simulation results
I Made Suartika   +2 more
doaj   +1 more source

Experimental investigation of PQ impact of different lighting systems in railway stations [PDF]

open access: yes, 2014
New lighting technologies are very important for their overall efficiency in reducing the absorbed energy and the operating and maintenance costs. However, they can introduce Power Quality (PQ) problems such as harmonic distortions, losses on the grid ...
BRENNA, MORRIS   +5 more
core  

Implementación de una interfaz gráfica de usuario en MATLAB para circuitos convertidores de CC-CA [PDF]

open access: yes, 2013
En este trabajo se muestra un software sobre la implementación de una interfaz gráfica de usuario (GUI) en el entorno de Matlab, para el análisis en simulación de los circuitos convertidores de CC – AC, de electrónica de potencia; de tipo monofásico y ...
Fernández Ramírez, Cristhian David   +1 more
core  

A New Damped Double-Tuned Filter to Improve Power Quality and System Performance for Nonlinear Household Loads

open access: yesIEEE Open Access Journal of Power and Energy
The growing use of nonlinear household appliances, such as LED lighting and inverter-based devices, has led to significant power quality problems. This is mainly due to harmonic currents altering the shape of voltage waveforms.
Faisal Irsan Pasaribu   +3 more
doaj   +1 more source

Inductor Compensation in Three Phase PFC Control with Decoupling the Input Voltage and Bus Voltage

open access: yesMATEC Web of Conferences, 2016
As the nonlinear structure of the boost ac/dc topology, the PFC is difficult to be controlled. The average state space theory has revealed that the choke current is determined by duty-ratio coupled with input voltage and bus voltage, which makes the high-
Luo Guang, Ai Wu, Chen Bing, Liu Yi
doaj   +1 more source

Home - About - Disclaimer - Privacy