Results 21 to 30 of about 187,132 (328)
Micro-thermocouple on nano-membrane: thermometer for nanoscale measurements [PDF]
A thermocouple of Au-Ni with only 2.5-μm-wide electrodes on a 30-nm-thick Si3N4 membrane was fabricated by a simple low-resolution electron beam lithography and lift off procedure.
A. Balčytis +3 more
semanticscholar +1 more source
With the development of smart grids, it has become possible to take demand-side resource utilization into account to improve the comprehensive benefits of combined heat and power microgrids (CHP-MGs).
Jiaqi Chang +4 more
doaj +1 more source
Heattransfer models in a sensitive element of the thermoconjugate temperature sensor in different conditions of heating up of the thermocouple are developed.
Atroshenko Yuliana K., Abramova Anna V.
doaj +1 more source
Fully Screen Printed Carbon Black-Only Thermocouple and the Corresponding Seebeck Coefficients
This work presents a thermocouple that is fully screen printed and consists exclusively of carbon black conductors. Two different carbon black inks were printed to form a thermocouple, which has been characterized regarding its output voltage.
Christina Offenzeller +3 more
doaj +1 more source
Thin-film thermocouple is widely used in temperature measurement because of its high temperature measurement accuracy and small size. In order to calibrate the temperature accurately with thin-film thermocouple, NiCr/NiSi thin-film thermocouple was ...
Guangyuan Zhao, Xin Li, Zhihui Liu
doaj +1 more source
An FEA based study of thermal behaviour of ultrasonically welded phosphor bronze sheets
The ultrasonic joining of phosphor bronze sheets is analyzed using a 3-D finite element model for the study and prediction of the thermal profiles at the weld interface.
Bharat Sanga +2 more
doaj +1 more source
Information-measuring System to Study the Thermocouple with Controlled Temperature Field
Error due to inhomogeneity is the main problem of thermocouples (TCs), e.g., during the operation of a type K TC, this error can reach 11-30 °C. Thus, metrological reliability of TCs is threatened by this error because there is a high risk of exceeding ...
Wang Jinfei +3 more
doaj +1 more source
Comparison of temperature change among different adhesive resin cement during polymerization process
Purpose: The aim of this study was to assess the intra-pulpal temperature changes in adhesive resin cements during polymerization. Materials and Methods: Dentin surface was prepared with extracted human mandibular third molars.
Murat Alkurt +3 more
doaj +1 more source
A Silicon Carbide Wireless Temperature Sensing System for High Temperature Applications
In this article, an extreme environment-capable temperature sensing system based on state-of-art silicon carbide (SiC) wireless electronics is presented.
Jie Yang
doaj +1 more source
Thermocouple for heating and cooling of memory metal actuators [PDF]
A semiconductor thermocouple unit is provided for heating and cooling memory metal actuators. The semiconductor thermocouple unit is mounted adjacent to a memory metal actuator and has a heat sink attached to it.
Wood, Charles
core +1 more source