In vitro Dosimetric Study of Biliary Stent Loaded with Radioactive 125I Seeds
Background: A novel radioactive 125I seed-loaded biliary stent has been used for patients with malignant biliary obstruction. However, the dosimetric characteristics of the stents remain unclear.
Li-Hong Yao +9 more
doaj +1 more source
Different germanium dopant concentration and the thermoluminescence characteristics of flat Ge-doped optical fibres [PDF]
The influence of elevated germanium concentration on the thermoluminesence characteristics of a novel form of fabricated flat optical fibre was examined. All the samples were irradiated with two nominal photon energies (6 MV and 10 MV) and 1.25 MeV gamma
Ahmad Fadzil, Muhammad Safwan +3 more
core
Experimental verification of acuros XB in the presence of lung-equivalent heterogeneities [PDF]
Acuros XB (AXB) is a deterministic algorithm that directly accounts for the effects of heterogeneities and improves the accuracy of photon dose calculations in radiotherapy. Nevertheless, the accuracy of AXB inside lung has not been yet fully examined by
Agramunt Chaler, Sebastià +4 more
core +2 more sources
Radiation induced vaporization of exoskeletal droplets as potential x‐ray acoustic contrast agents
Abstract Background In vivo dosimetry is a crucial component of ensuring accurate and safe radiation therapy (RT) delivery, but many existing techniques face challenges such as low signal‐to‐noise ratio (SNR), which can limit their clinical applicability.
Mohamed Elsayed Eldib +5 more
wiley +1 more source
Dosimetry for FLASH Radiotherapy: A review of dosimetric systems
FLASH radiotherapy (FLASH-RT) is a promising approach to cancer treatment, characterized by the delivery of high doses of radiation in a short period of time, within fractions of seconds.
Karoline Feitoza Suzart +1 more
doaj +1 more source
A measurement of the radiation dose to LDEF by passive dosimetry [PDF]
The results from a pair of thermoluminescent dosimeter experiments flown aboard the Long Duration Exposure Facility (LDEF) show an integrated dose several times smaller than that predicted by the NASA environmental models for shielding thicknesses much ...
Blake, J. B., Imamoto, S. S.
core +1 more source
Analysis of the results of personal monitoring to ionizing radiation at workplaces
Background The paper presents the results of dosimetric measurements routinely performed by the Radiation Protection Department of the Nofer Institute of Occupational Medicine (NIOM) in Łódź in 2022 for people occupationally exposed to X and γ radiation.
Sylwia Papierz +1 more
doaj +1 more source
ASSESSMENT OF PCXMC MONTE CARLO SIMULATIONS IN SLOT-SCANNING-BASED EXAMINATIONS: COMPARISON WITH IN-PHANTOM THERMOLUMINESCENT DOSIMETRY. [PDF]
Piai A +6 more
europepmc +1 more source
Dosimetric characteristics of fabricated Ge-doped silica optical fibre for small-field dosimetry
We study 3 mm long germanium-doped (Ge-doped) silica fibres for small-field dosimetry, seeking to overcome spatial resolution and charged-particle disequilibrium issues, also any associated dose deviation from that of computerised treatment plan dose ...
S.E. Lam +5 more
doaj +1 more source
Background: Extensive use of computed tomography (CT)-scan imaging is associated with an increase in cumulative dose. Stereoradiography by electro-optical system (EOS) is an X-ray imaging technology that can reduce patient absorption dose, and increase ...
Mahdie Ghadimi +5 more
doaj +1 more source