Results 41 to 50 of about 57,908 (201)

Correlation of size specific dose estimates with organ dose in abdominal spectral computed tomography

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 10, October 2026.
Abstract Background In abdominal spectral Computed Tomography (CT), organ dose assessment is important for radiation safety but remains challenging due to the complexity of Monte Carlo (MC) simulations. Purpose This study aimed to compare the correlations of three size‐specific dose estimate (SSDE) metrics (including the central slice SSDEcenter, the ...
Tian Qin   +6 more
wiley   +1 more source

Preclinical feasibility of EPID‐based transit dosimetry for total body irradiation

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 9, September 2026.
Abstract Background Conventional extended‐distance total body irradiation (TBI) is commonly verified using point dosimeters, which provide limited spatial information and require additional handling during a prolonged treatment procedure. A portable charge‐coupled device (CCD)‐based electronic portal imaging device (EPID) positioned downstream of the ...
Tetsu Nakaichi   +10 more
wiley   +1 more source

Comparative Evaluation of Four Stereotactic Radiosurgery Planning Approaches for Treatment of Posterior Choroidal Melanoma

open access: yesJournal of Medical Radiation Sciences, Volume 73, Issue 3, Page 250-258, September 2026.
This study evaluated four stereotactic radiosurgery planning approaches for posterior choroidal melanoma (CM). Analysis of thirteen CM cases resulted in a clinically meaningful reduction in dose to the brain for Brainlab Elements modulated arcs (BE) and Varian Eclipse HyperArc modulated arcs (HA) compared to Brainlab iPlan dynamic conformal arc therapy
Robert Nigro   +5 more
wiley   +1 more source

Quality Control Program for the Hanford External Dosimetry Thermoluminescent Processing System

open access: yes, 1992
The Hanford External Dosimetry Program is operated by Pacific Northwest Laboratory for the US Department of Energy (DOE). The program records official external occupational radiation doses for all Hanford Site employees and visitors in compliance with ...
Baumgartner, W. V.   +5 more
core   +2 more sources

Thermoluminescent composites of sintered synthetic-topaz/in situ corundum for dosimetry by a novel reversible process

open access: yesHeliyon
Topaz (Al2F1·44(OH)0·56SiO4)/corundum (Al2O3) composites were prepared by a facile and novel reversible process from the sintering of synthetic topaz and AlF3 powders, with corundum formed in situ into the topaz matrix.
S.A. Sinclair   +5 more
doaj   +1 more source

Intercomparisons as an important element of quality assurance in metrology of ionising radiation [PDF]

open access: yesNuclear Technology and Radiation Protection, 2015
Intercomparisons are important activities performed to ensure that the services provided by calibration laboratories to end-users follow internationally accepted standards. Ionizing radiation dosimetry intercomparisons are usually of two types -
Živanović Miloš Z.   +5 more
doaj   +1 more source

Transporter‐Associated Therapeutic Efficacy of an SMVT‐Targeted Boron Carrier in Boron Neutron Capture Therapy

open access: yesCancer Science, Volume 117, Issue 9, Page 2555-2566, September 2026.
The transporter‐associated BNCT strategy using BBCIP with or without BPA according to tumor transporter characteristics. BPA showed greater efficacy in LAT1‐dominant F98 glioma, whereas BBCIP was more effective in SMVT‐high CRL1666 tumors, suggesting the potential utility of transporter‐based boron carrier selection in BNCT.
Kenichiro Eza   +15 more
wiley   +1 more source

Out-door radiation level measurement in Abeokuta, Nigeria, by thermoluminescent dosimetry

open access: yes, 2007
Environmental radiation level and its spatial variability have been investigated at 34 locations in Abeokuta and environs using the technique of thermoluminescent dosimetry (TLD) with LiF phosphor calibrated with a 137Cs standard source operating at a ...
Vincent, U E   +3 more
core   +1 more source

Use of calcium sulfate for thermoluminescent thermal dosimetry

open access: yes, 1992
International audienceThe use of manganese doped calcium sulfate irradiated for thermal dosimetry is proposed. This thermoluminescent compound shows a high sensitivity to temperatures ranging between 40°C and 50°C.
Aletti, Pierre   +4 more
core   +1 more source

Development of a Polydimethylsiloxane‐Based Flexible Digital Bolus Dosimeter: From Unit‐Cell Characterization to Linear Array for Skin‐Dose Distribution Verification

open access: yesphysica status solidi (a), Volume 223, Issue 15, 5 August 2026.
A flexible digital bolus dosimeter platform is proposed to address the challenges of surface‐dose monitoring. The study evaluates point‐dose performance using an IDE substrate and extends this to spatial dose distributions using an fPCB‐integrated 24‐pixel array.
Moo‐Jae Han   +7 more
wiley   +1 more source

Home - About - Disclaimer - Privacy