Results 71 to 80 of about 1,281 (219)

Analysis of the effect of the heat stabilizer outer surface finning on soil cooling efficiency

open access: yesИзвестия Томского политехнического университета: Инжиниринг георесурсов
Relevance. The construction of buildings and structures in permafrost conditions is associated with the problem of soil thawing. To prevent this phenomenon, heat stabilizer have proven themselves good in practice.
Alexander Ya. Gilmanov   +2 more
doaj   +1 more source

Heat Transfer Characteristics of Novel Resin Impregnated Paper Converter Transformer Valve‐Side Bushing With Two‐Phase Closed Thermosyphon

open access: yesHigh Voltage, Volume 10, Issue 5, Page 1221-1234, October 2025.
ABSTRACT Resin impregnated paper (RIP) converter transformer valve‐side bushings are the key equipment in converter stations. Local overheating of the RIP core not only reduces the transmission efficiency but also causes insulation failure of converter transformers.
Qingyu Wang   +5 more
wiley   +1 more source

NEW APPROACH TO MODELLING THE FORMATION OF LARGE-SIZED THERMOSIPHONS THERMAL REGIME FOR USING GEOTHERMAL HEAT

open access: yesИзвестия Томского политехнического университета: Инжиниринг георесурсов, 2019
The relevance of the research is caused by the necessity to develop mathematical models of thermophysical processes occurring in thermosiphons. These models are significantly less complex than the known ones, where sophisticated hydrodynamics problems ...
Vyacheslav I. Maksimov   +1 more
doaj   +1 more source

Heat Exchanger Planning Thermosiphon Reboiler for Thermal Oil Heaters at PT. Season Mas Oleo Bemical

open access: yes, 2007
82 HalamanAlat Penukar Panas merupakan bagian dari alat industri kimia (bagian dari unit operasi). Alat ini memegang peranan penting dalam satuan operasi. Materi itulah yang menjadi dasar bagi penulis untuk merancang salah satu materi panas jenis alat
Erwin
core   +1 more source

Modeling and optimization of a thermosiphon for passive thermal management systems

open access: yes, 2012
An optimally designed thermosiphon for power electronics cooling is developed. There exists a need for augmented grid assets to facilitate power routing and decrease line losses.
Loeffler, Benjamin Haile
core   +1 more source

Using of thermosiphon solar collector in an air heating system of passive house [PDF]

open access: yes, 2016
In this article the using of thermosiphon solar collectors for system air heating of premises of passive houses was examined. The research determination the air velocity and air temperature in the space of experimental module were conducted. According to
Christina Kozak   +5 more
core   +1 more source

ONE-DIMENSIONAL MIXTURE MODEL CODE FOR THE MODELING OF TWO-PHASE FLOW THERMOSIPHON

open access: yes, 2023
International audienceThe numerous coupled physical phenomena involved in natural circulation two-phase flow loops make their analytical or numerical modelization difficult.
Colin, Catherine   +2 more
core   +1 more source

Performance test and controller design of passive thermosiphon beam

open access: yes, 2018
Thermosiphon beams fall under the integrated system of Air Conditioning and Mechanical Ventilation (ACMV). An ACMV thermosiphon beam system is designed to meet the environmental comfort needs in a closed space environment. The traditional ACMV systems
Ramesh, Arpitha Rani
core  

An improved methodology for thermal calculation and design optimization of a thermosiphon waste heat boiler for CCPP

open access: yesCase Studies in Thermal Engineering
The study is dedicated to enhancing design and computational methodologies for thermosiphon waste heat boilers (WHB) within combined cycle power plants (CCPP). The optimized WHB design and an improved thermal calculation approach are shown.
Iurii Dolganov   +3 more
doaj   +1 more source

Energy-efficient technologies for thermal treatment and drying of food products [PDF]

open access: yesJournal of Central European Agriculture
A study of the process of heat treatment, concentration, and drying of food products in a thermomechanical unit with a rotary thermosiphon was conducted. Analysis of experimental data revealed that, compared to convective drying, the dryers with a rotary
Oleg Burdo   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy