Results 71 to 80 of about 1,078,566 (277)

Inflammation Unchecked: Concurrent Kawasaki Disease and Stevens‐Johnson Syndrome in an 18‐Month‐Old Child

open access: yes
Arthritis Care &Research, EarlyView.
Catherine Deffendall   +6 more
wiley   +1 more source

Self‐Sintering Ionogel Binder for Flexible, Recyclable, and Healable Printed Giant Magnetoresistive Sensors

open access: yesAdvanced Functional Materials, EarlyView.
ABSTRACT Electronic waste has emerged as a major environmental challenge, driven by the massive consumption and a limited lifetime of modern electronic devices, stimulating the development of sustainable electronics. Here, an all‐biomaterial gelatin‐choline‐citric acid ([Ch][CA]) ionogel is developed as an active binder to realize self‐sintered ...
Lin Guo   +10 more
wiley   +1 more source

Regulated Ion‐Diffusion Hydrogels for Subtle and Multimodal Temperature‐Strain Sensing in Wound Monitoring

open access: yesAdvanced Functional Materials, EarlyView.
A soft, dual‐channel hydrogel patch enables simultaneous detection of wound temperature and strain by integrating ion‐diffusion‐mediated thermoelectric and resistive sensing. The conformal design maintains stable performance during motion, capturing subtle inflammatory and mechanical changes for continuous wound monitoring.
Yu Fang   +7 more
wiley   +1 more source

Chemically Cross-Linked Poly(acrylic-co-vinylsulfonic) Acid Hydrogel for the Delivery of Isosorbide Mononitrate [PDF]

open access: yes, 2013
We report synthesis, characterization, and drug release attributes of a series of novel pH-sensitive poly(acrylic-co-vinylsulfonic) acid hydrogels.
Talib Hussain   +9 more
core   +1 more source

Historical Foundation and Practical Guideline for Ferroelectric Switching Kinetic Studies

open access: yesAdvanced Functional Materials, EarlyView.
The P and U pulses in the conventional PUND measurements are not identical because of the interplay between switching current and the measurement circuit components. This circuit effect can lead to a shift in polarization transients and misinterpreted physics in the switching kinetics.
Yi Liang, Pat Kezer, John T. Heron
wiley   +1 more source

Swelling behaviour of poly(methylmethacrylate) thick resist layers in deep X-ray lithography

open access: yesJournal of Synchrotron Radiation, 2003
The understanding and optimization of lithographic conditions are particularly important for irradiation of thick resist layers in deep X-ray lithography. The causes and consequences of radiation-induced formation and accumulation of gaseous species inside the poly(methylmethacrylate) (PMMA) resist matrix are discussed.
Khan-Malek, C., Das, S.
openaire   +2 more sources

Electrospun Wood‐Derived Biopolymers as Electrodes in Electrochemical Energy Storage Technologies

open access: yesAdvanced Functional Materials, EarlyView.
Electrospinning transforms wood‐derived cellulose and lignin into architecturally defined, binder‐free carbon electrodes with tuneable porosity and functionality. This review shows how fibre design enables decoupled charge and mass transport, enhancing performance across battery systems, while identifying key challenges in spinnability, scalability ...
Michael W. Thielke   +3 more
wiley   +1 more source

Lignocellulosic Composites from Acetylated Sunflower Stalks

open access: yesApplied Sciences, 2019
Sunflower stalks could be an alternative raw material for use in the particleboard industry since the requirements of P1 general purpose boards for use in dry conditions and P2 boards for interior fitment for use in dry conditions are easily satisfied ...
Antonios N. Papadopoulos   +2 more
doaj   +1 more source

Oil palm trunk polymer composite: Morphology, water absorption, and thickness swelling behaviours

open access: yesBioResources, 2012
In this research, impregnated oil palm trunks (OPT) and polymer composites were prepared from a combination of dried oil palm trunks with phenol formaldehyde (PF) and urea formaldehyde (UF) resin in different resin percentages using an impregnation method.
C. K., Abdullah   +4 more
openaire   +2 more sources

Implantable Ionic Memristors Based on Natural Polymer Heterojunctions

open access: yesAdvanced Functional Materials, EarlyView.
We report an implantable natural polymer‐based ionic memristor composed of hyaluronic acid, chitosan, and PDMS. The device achieved 98.94% accuracy in MNIST classification while reducing training time by 36.8% compared with a conventional artificial neural network (ANN).
Dong‐yup Lee   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy