Results 101 to 110 of about 1,050,547 (176)

Rigid Bronchoscope

open access: yes
The Rigid Bronchoscope (circa 1950s) was manufactured by American Cystoscope Makers Inc. and consists of a hollow outer scope with suction/irrigation channels and removable inner scope complete with optical channel, external light source and a biopsy ...
Museum of Medical History,
core   +1 more source

Failure of the classic LMA and Aintree catheter with bronchoscope for tracheal intubation while performing manual inline stabilisation

open access: yes, 2008
Despite obtaining good views of the laryngeal inlet with the bronchoscope and passing the tip of the fibreoptic bronchoscope into the subglottic space, the authors were unable to railroad the Aintree catheter (AIC) off the bronchoscope into the laryngeal
Donaldson, A. E.   +3 more
core  

Ultra-thin Cuffed Endotracheal Tube (Tritube®)

open access: yes
This chapter aims to provide an overview of the ultra-thin cuffed endotracheal tube (ETT), starting with the concept that inspired its design and a detailed description of the tube’s specifications.
Shallik, Nabil A.   +2 more
core   +1 more source

Evaluating the effect of operator experience and bronchoscope type in performance of simulated bronchial wash

open access: yes, 2015
Broncho-alveolar lavage (BAL) and bronchial wash (BW) are commonly used diagnostic and therapeutic techniques in the intensive care unit. The ability to perform BW or BAL safely is dependent on operator, equipment, and patient factors.1 Intuitively ...
Whetton, E., McGrath, B.; id_orcid
core   +2 more sources

Cone-Beam CT–Guided Thin Linear EBUS Bronchoscopic Biopsy of a Non- Peripheral Lung Nodule: Highlighting the Effect of Bronchoscopic Tools on CT-to-Body Divergence: A Case Report

open access: yes
Abstract Background: Accurate bronchoscopic biopsy of non-peripheral pulmonary nodules adjacent to proximal segmental airways remains challenging. Such lesions lie beyond the reach of standard endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) and resist accurate bronchoscope ...
Tajalli Saghaie¹   +3 more
openaire   +1 more source

Outbreak of pulmonary Pseudomonas aeruginosa and Stenotrophomonas maltophilia infections related to contaminated bronchoscope suction valves, Lyon, France, 2014.

open access: yes, 2016
International audienceIn April 2014, pulmonary Pseudomonas aeruginosa and Stenotrophomonas maltophilia co-infections potentially related to bronchoscopic procedures were identified in the intensive care units of a university hospital in Lyon, France.
Guy, Marine   +12 more
core   +1 more source

Long Term Efficacy and Safety of Bronchoscopic Thermal Vapor Ablation in Patients with COPD: A Retrospective Study of 50 Patients

open access: yesInternational Journal of COPD
Barak Pertzov,1– 4 Merav Ben Avraham,1,2 Eldar Priel,3– 5 Lev Freidkin,1,2 Dror Rosengarten,1,2 Mordechai Reuven Kramer1,2 1Pulmonary Division, Rabin Medical Center, Petach Tikva, Israel; 2Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv ...
Pertzov B   +5 more
doaj  

UTILITY OF A 3.5-MM THIN BRONCHOSCOPE WITH A 1.7-MM WORKING CHANNEL FOR DIAGNOSIS OF PERIPHERAL PULMONARY LESIONS [PDF]

open access: yesChest, 2007
Masahide Oki   +5 more
openaire   +1 more source

Home - About - Disclaimer - Privacy