Results 171 to 180 of about 4,040 (212)

Experimental Technique to Measure Thoron Generation Rate of Building Material Samples Using RAD7 Detector [PDF]

open access: yesRadiation Measurements, 2013
Thoron (220Rn) is the second most abundant radon isotope in our living environment. In some dwellings it is present in significant amount which calls for its identification and remediation. Indoor thoron originates mainly from building materials. In this
Csaba Szabó
exaly   +2 more sources
Some of the next articles are maybe not open access.

Related searches:

Characteristics of thoron and thoron progeny in Canadian homes

Radiation and Environmental Biophysics, 2010
Naturally occurring isotopes of radon in indoor air are identified as the second leading cause of lung cancer after tobacco smoking. Radon-222 (radon gas) and radon-220 (thoron gas) are the most common isotopes of radon. While the radon equilibrium factor is well established, the equilibrium factor between thoron progeny and thoron gas is still not ...
Jing, Chen   +3 more
openaire   +2 more sources

Indoor Radon, Thoron, and Thoron Daughter Concentrations in Korea

International Congress Series, 2005
A nationwide survey for radon (222Rn), thoron (220Rn), and thoron daughters has been conducted. The arithmetic mean of annual radon concentration in Korean dwellings was 53.4±57.5 Bq/m3. The indoor radon concentration showed a lognormal distribution with a geometric mean and its standard deviation of 43.3±1.8 Bq/m3. The arithmetic mean of annual thoron
Shinji Tokonami, C K Kim, C S Kim
exaly   +2 more sources

A method for the determination of thoron and thoron progeny concentration at workplaces and thoron concentration in calibration chambers

Radiation Protection Dosimetry, 2008
A new method to determine the air concentration of (220)Rn, commonly referred to as thoron, has been developed. The method is insensitive to the presence of any concentration of (222)Rn. Air turbulence, humidity and temperature do not influence the measurement.
R, Falk, G, Akerblom, Leif, Nyblom
openaire   +2 more sources

Evaluation of Radiation Hazards Created by Thoron and Thoron Daughters

American Industrial Hygiene Association Journal, 1960
In estimating the relative hazards created by the inhalation of thoron and thoron daughters, certain assumptions were required because of the incomplete knowledge of the biological behavior of these elements or were employed to simplify the calculations.
R L, BLANCHARD, D A, HOLADAY
openaire   +2 more sources

CFD modelling of thoron and thoron progeny in the indoor environment

Radiation Protection Dosimetry, 2011
Thoron (220Rn) exhalation from building materials has become increasingly recognised as a potential source for radiation exposure in residences. However, contrary to radon (222Rn), limited information on thoron exposure is available. The purpose of this study is to estimate the concentration of thoron and its progeny products in a typical Dutch living ...
G, de With, P, de Jong
openaire   +2 more sources

Thoron standard source

Applied Radiation and Isotopes, 2019
Thoron (220Rn) has been identified as a possible health concern in specific places such as monazite processing plants and (rare-earth) mines. The short half-life of thoron (55.8 s) makes thoron calibration sources and thoron chambers less common than the corresponding radon (222Rn) ones.
Robert, Lindsay   +4 more
openaire   +2 more sources

Measurement of Thoron in the Breath

Physics in Medicine and Biology, 1958
A method of measuring the thoron content of the breath of patients who have been injected with colloidal thorium dioxide as a radiological contrast medium, is described. The levels are sufficiently high for the decay of the thoron to be observed using only four litres of breath, being in the range 250 to 2000 μμc per litre, and they can be used to ...
J, RUNDO, A H, WARD, P G, JENSEN
openaire   +2 more sources

Impact of Wind Speed on Response of Diffusion-Type Radon-Thoron Detectors to Thoron [PDF]

open access: yesInternational Journal of Environmental Research and Public Health, 2020
Air exchange through a porous medium depends partly on a pressure gradient induced in it, i.e., air-flow conditions of the outer air. Consequently, response of diffusion-type detectors to radon and thoron may vary with air-flow conditions surrounding the detectors.
Masahiro Hosoda   +2 more
exaly   +3 more sources

Characteristic of Thoron (220Rn) in Environment

Applied Radiation and Isotopes, 2017
This paper describes importance of 220Rn (hereafter thoron) progeny measurement for the dose estimation. Although the spatial distribution of thoron activity concentration strongly depends on the distance from wall surface as an indoor thoron source), a homogeneous distribution was expected to be observed for 212Pb activity concentration which was one ...
Masahiro Hosoda   +2 more
exaly   +3 more sources

Home - About - Disclaimer - Privacy