Removing Oxide Layers and Retaining Oxide‐Free Steel Surfaces by Polishing in Oxygen‐Free Atmosphere
In this study, the efficacy of wet mechanical polishing under an oxygen‐free atmosphere for deoxidation and the retention of an oxide‐free steel surface are elucidated using X‐ray photoelectron spectroscopy. The methodology proved successful; however, the results were highly dependent on the preparation of the solvents used to clean the samples after ...
Friedrich Bürger +2 more
wiley +1 more source
Investigating hepatic fibrosis heterogeneity by three-dimensional imaging in metabolic dysfunction-associated steatotic liver disease. [PDF]
Yigit B +23 more
europepmc +1 more source
Powder Optimization Strategies for Binder Jetting Printing of BaTiO3 and Ba0,6Sr0,4TiO3 Ceramics
Powder optimization is investigated to enable binder jetting of BaTiO3 and Ba0.6Sr0.4TiO3 ferroelectric ceramics. The antagonistic relationship between flowability and binder compatibility is addressed through binder impregnation of granulated powders and fumed silica addition to fine powders.
Fanny Pruvost +4 more
wiley +1 more source
Three-Dimensional Imaging-Guided Safe Para-Aortic Lymph Node Dissection Using the Inferior Mesenteric Artery as an Intraoperative Landmark in a Patient with Renal Vascular Variation. [PDF]
Idegami D +7 more
europepmc +1 more source
Influence of an Oxygen‐Free Atmosphere on Diamond‐Single‐Grain Scratching of Ti–6Al–4V
Single‐grain scratching of Ti–6Al–4V is investigated under controlled, oxygen‐free, and ambient atmospheres using a novel experimental setup with in situ high‐speed imaging. The approach enables direct observation of chip formation and adhesion under suppressed oxidation.
Berend Denkena +2 more
wiley +1 more source
Imaging Of A Three Dimensional Model System For Invasive Growth Of Trophoblasts
Gerit Moser +5 more
openalex +1 more source
This work explores the reduction of nickel oxide layers using dielectric barrier discharge plasma in an argon–hydrogen atmosphere. The results reveal a strong temperature dependence, enabling complete reduction of thick oxide layers at 200°C within seconds.
Maria Argirusi +5 more
wiley +1 more source
Three-Dimensional Imaging Sensor-Based Non-Contact Measurement of Neonatal Head Circumference in Incubators. [PDF]
Win KD, Kawasue K, Kaneko M.
europepmc +1 more source
Three-dimensional imaging and analysis of entire peripheral nerves after repair and reconstruction
Christos Bikis +7 more
openalex +2 more sources

