Results 1 to 10 of about 5,801 (208)

Efficiency-optimised modulation technique of three-level NPC inverter

open access: yesThe Journal of Engineering, 2018
The three-level NPC inverter has many advantages, such as the characteristics of high output power, low device stress, and low harmonic distortion of output waveform.
Ning Li   +3 more
doaj   +2 more sources

Current Sensorless Control Algorithm for Single-Phase Three-Level NPC Inverter [PDF]

open access: yesElectrical, Control and Communication Engineering, 2014
The current measurement is becoming a challenging task in power converters operating at high switching frequencies, moreover traditional control system requires two control loops - first (slow) regulates DC-link voltage, second (fast) controls the shape ...
Suzdalenko Alexander   +2 more
doaj   +3 more sources

Phase disposition PWM control topology based: A novel multilevel inverter with reduced switch for power electronics applications. [PDF]

open access: yesHeliyon
In the field of industrial drive applications, a neutral point clamped multilevel inverter (NPC MLI) is an extensively used option. The NPC MLI architecture involves more number of components for higher level and higher switching frequency operation.
Y VS, R V.
europepmc   +2 more sources

Simplified MPC Algorithm of NPC Three-level Inverter Based on SVPWM

open access: yesZhejiang dianli, 2022
The traditional control method of the NPC (neural point clamped) three-level inverter is unable to effectively reduce CMV (common-mode voltage) and needs a large calculation quantity because of the zero vector involved modulation or rolling optimization.
QIAN Jinyue   +4 more
doaj   +2 more sources

Robust vector control of SynRM using a three-level NPC inverter [PDF]

open access: yesEPJ Web of Conferences
This research aims to evolve a robust vector command of a 3-phase synchronous reluctance motor (SynRM). The conventional 2-level inverter is replaced by a 3-level neutral-point-clamped (NPC) inverter.
Fahassa Chaymae   +2 more
doaj   +2 more sources

A fault-tolerance topology of three-level four-leg NPC inverter

open access: yesGong-kuang zidonghua, 2016
In view of problem that it is difficult to accurately locate device failure of inverter, a fault tolerance topology of three-level four-leg NPC inverter was proposed.
QIU Shiguang, LI Siguang
doaj   +2 more sources

Three-Level NPC Dual-Buck Inverter Designed to Safety-Critical Applications [PDF]

open access: yes2020 IEEE 14th International Conference on Compatibility, Power Electronics and Power Engineering (CPE-POWERENG), 2020
This paper presents a three-phase three-level NPC (neutral point-clamped) Dual-Buck inverter topology suitable to increase fault-tolerant capability to safety-critical applications. Using the proposed topology, it is possible to achieve energy processing capability in case of several failure modes.
Cordeiro, Armando   +2 more
openaire   +2 more sources

Five-level F-type inverter with buck-boost converter-based equalization channels

open access: yesAlexandria Engineering Journal, 2023
Multilevel inverters have been widely used in various applications, as they provide output voltage with better quality, lower dv/dt, and lower Total Harmonic Distortion (THD).
Ahmed A. Elserougi   +2 more
doaj   +1 more source

Grid-Tied Neutral Point Clamped based Centralised Photovoltaic Inverter with Improved DC Link Voltage Balancing and Harmonic Minimisation Control

open access: yesPower Electronics and Drives, 2021
This paper proposes an improved space vector pulse width modulation (SVPWM) based DC link voltage balancing control of a three-phase three-level neutral point clamped (NPC) centralised inverter supplying the generated power from photo voltaic (PV) array ...
Bhowmick Supratik   +3 more
doaj   +1 more source

Grid-Connected Solar PV System with Maximum Power Point Tracking and Battery Energy Storage Integrated with Sophisticated Three-Level NPC Inverter

open access: yesInternational Transactions on Electrical Energy Systems, 2023
In this research, a solar photovoltaic system with maximum power point tracking (MPPT) and battery storage is integrated into a grid-connected system using an improved three-level neutral-point-clamped (NPC) inverter.
D. Ravi Kishore   +6 more
doaj   +1 more source

Home - About - Disclaimer - Privacy