Results 91 to 100 of about 6,244,971 (203)

Loop Current Characteristics of A Thyristor Controlled Series Capacitor

open access: yesIEEJ Transactions on Power and Energy, 1997
Junya Matsuki, Keiichi Ikeda
openaire   +2 more sources

Phase selection and fault section identification in thyristor controlled series compensated line using discrete wavelet transform

open access: yes, 2004
Discrete wavelet transform is used to analyze faulty signals for a transmission system employing a thyristor controlled series capacitor at the midpoint of a line.
Samantray, S. R., Dash, P. K.
core   +1 more source

A non-unit adaptive pilot protection for HV transmission line interlinked with off-shore grid scale wind energy and controllable series compensator

open access: yesResults in Engineering
Conventional non-unit distance relays often malfunction when protecting transmission lines integrated with large-scale wind farms and series Flexible AC Transmission System (FACTS) controllers such as the Thyristor-Controlled Series Capacitor (TCSC ...
Andaleeb Ali, Attaullah Khawaja
doaj   +1 more source

Mitigating of Sub-synchronous Resonance in a Series-Compensated Hybrid System with Steam and Wind Turbine Using FACTS Controllers

open access: yesMajlesi Journal of Electrical Engineering
The growing requirement to the clean and renewable energy has led to the rapid development of wind power systems all over the world. With increasing use of wind power in power systems, impact of the wind generators on sub-synchronous resonance (SSR) is ...
Hossein Hosseini, Behruz Tousi
doaj  

Synchronous Voltage Reversal Control of Thyristor Controlled Series Capacitor

open access: yes, 2002
Series compensation of transmission lines is an effectiveand cheap method of improving the power transmission systemperformance. Series capacitors virtually reduces the length ofthe line making it easier to keep all parts of the power systemrunning in ...
Ängquist, Lennart
core   +2 more sources

Analysis of the Series Resistance-Capacitance Circuit controlled by Thyristor. [PDF]

open access: yes, 1970
In case the single-phase A.C is applied to the series R-C circuit is controlled by thyristor, the phase relation between the cut-off angle and the firing one of a thyristor depends upon the load characteristic.
加納, 敏三
core  

A Laboratory-Scale Thyristor Controlled Series Capacitor

open access: yesIEEJ Transactions on Power and Energy, 1996
Matsuki, Junya   +2 more
openaire   +2 more sources

Estimating damping effectiveness of BPA`s thyristor controlled series capacitor by applying time and frequency domain methods to measured response

open access: yes, 1995
Recently, a 500-kV thyristor controlled series capacitor (TCSC) was installed in the Bonneville Power Administration system in the northwestern United States. Extensive field testing has included modulation experiments to determine the effect of the TCSC
Donnelly, M. K.   +2 more
core  

High-power hybrid commutated converter for carbon-neutral power transmission. [PDF]

open access: yesNat Commun
Xu C   +7 more
europepmc   +1 more source

Home - About - Disclaimer - Privacy