An Inkjet‐Printed Platinum‐Based Temperature Sensing Element on Polyimide Substrates
An inkjet‐printed, meander‐structured, nanoparticle platinum‐based resistive temperature sensors on polyimide substrates are demonstrated as proof‐of‐concept. Optimized sintering at 250°C enables stable conductive structures. The Pt100‐ and Pt1000‐type sensors exhibit linear resistance–temperature characteristics with stable TCR in the 20°C–80°C range,
Shawon Alam +6 more
wiley +1 more source
The tilt table test is useful for the diagnosis of vasovagal syncope and should not be abolished. [PDF]
Chrysant SG.
europepmc +1 more source
Demographic and clinical features of pediatric patients with orthostatic intolerance and an abnormal head-up tilt table test; A retrospective descriptive study [PDF]
Anand Gourishankar +5 more
openalex +1 more source
Laser wire directed energy deposition process was leveraged to fabricate large scale NiTi alloy wall. Evaluation of build‐height‐dependent tribo‐mechanical properties revealed significant differences in location specific sample characteristics. The middle region achieved optimal performance (superior wear resistance, balanced strength‐ductility ...
Hyunsuk Choi +5 more
wiley +1 more source
Skin sympathetic nerve activity as a biomarker for syncopal episodes during a tilt table test. [PDF]
Kumar A +10 more
europepmc +1 more source
Orthostatic-induced Hypotension Attenuates Cold Pressor Pain Perception
In recent years, numerous studies have established a connection between blood pressure and nocioception. While this connection is well documented in the literature, its underlying physiological mechanisms have yet to be elucidated.
Drury, Daniel G., Wonders, Karen Y.
core
Challenges during Flash Lamp Annealing of Aerosol‐Deposited Barium Titanate Films
Aerosol deposition is used to rapidly deposit barium titanate films with thicknesses ranging from 2 to 16 μm at room temperature, eliminating the need for further densification. However, to recover the electromechanical properties, annealing is required, which limits the usage of temperature‐sensitive substrates.
Michel Kuhfuß +7 more
wiley +1 more source
Purpose: Syncope remains a common medical problem. Recently, the role of dedicated syncope units and implantable loop recorders has emerged in the investigation of unexplained syncope.
Stefanos Archontakis +14 more
doaj +1 more source
The Differences in the Diagnostic Profile in Children with Vasovagal Syncope between the Result of Head-Up Tilt Table Test. [PDF]
Kolarczyk E +3 more
europepmc +1 more source
Syncope and seizures of psychogenic origin: Identification with head‐upright tilt table testing [PDF]
Blair P. Grubb +6 more
openalex +1 more source

