Results 81 to 90 of about 13,261 (265)
ABSTRACT Rocking podium isolation systems have gained significant research interest as a method of limiting seismic demands on superstructures and eliminating residual post‐earthquake drifts through self‐centring behaviour. However, while numerous models of varying complexity, including analytical, phenomenological, and physical formulations, have been
Marawan Zaki +2 more
wiley +1 more source
This study mainly explores the instability characteristics of roadways near faults in the working face. Taking the 51104 transportation roadway of the 51104 working face in Shengxin Coal Mine as the main research object, through theoretical analysis, borehole inspection, numerical simulation and on‐site mine pressure observation, the instability ...
Shuaifeng Yin +4 more
wiley +1 more source
ABSTRACT This study addresses the influence of fibre architecture on the mechanical properties of vacuum‐infused glass fibre reinforced polymer (GFRP) composites at elevated temperatures (ET). Laminates with three different fibre configurations—unidirectional (UD), bidirectional 0°/90° cross‐ply (BD), and ±45° off‐axis angle‐ply (OA) – were tested in ...
Eloísa Castilho +4 more
wiley +1 more source
Char Layer Thickness Evolution During Structural Timber Fire Experiment and Final Density Profile
ABSTRACT This paper evaluates several non‐destructive experimental methods for determining the char layer thickness and its density profile in structural timber samples exposed to standard ISO 834 fire curve experiments. Microwave echo pulse, ultrasonic echo pulse, X‐ray computed tomography, and resistance drilling were evaluated.
Fernando Pérez Pérez +4 more
wiley +1 more source
ABSTRACT Fire sources in actual compartment fires exhibit a predominantly uneven spatial distribution. In this context, the impact of the height and location of the fire source, as well as the heat release rate (HRR) of the fire, on the thermal characteristics of Externally Venting Flames (EVF) is experimentally investigated.
Dionysios I. Kolaitis +1 more
wiley +1 more source
ABSTRACT Heat induced delamination (HID) is a phenomenon in engineered wood products which may result in the detachment of the bonded timber lamellae before charring propagates to the bond line interphase. This study aims to correlate the thermal degradation of two 1‐c‐polyurethane adhesives at the microscale to the thermo‐hydro‐mechanical behaviour of
A. Čolić +4 more
wiley +1 more source
Global climate change is a major challenge for forestry because it fundamentally alters the growth conditions of tree species. Sycamore maple (Acer pseudoplatanus L.), often overlooked in forest management, is increasingly recognized as a valuable ...
Zdeněk Vacek +11 more
doaj +1 more source
ABSTRACT This research was conducted within the framework of project SI2.825082, funded by the European Commission—DG GROW. The project's objective was to finalise a European approach for assessing the fire performance of façades under medium and large fire exposure conditions.
Péter Tóth +7 more
wiley +1 more source
Monoculture forestry dominates industrial timber production because it maximizes short rotation yields, simplifies management, and facilitates efficient mechanization.
Derek M. Johnson +2 more
doaj +1 more source
Charring Behaviour of Mass Timber: A Comparison of Thin Intumescent Coatings and Plasterboard
ABSTRACT This study compares the charring behaviour of mass timber under varied heating conditions when protected by either different thin intumescent coating types or fire‐rated plasterboard layers. Bench‐scale fire experiments were conducted using the Heat‐Transfer Rate Inducing System (H‐TRIS).
Stavros Spyridakis +4 more
wiley +1 more source

