Results 11 to 20 of about 19,543 (52)
Critical line-to-line faults (LLFs) and line-to-ground faults (LGFs) in photovoltaic (PV) systems are the most difficult faults to detect not only by conventional protection devices, but also modern fault detection schemes.
Sherko Salehpour +4 more
doaj +1 more source
In asynchronous grid connection mode, the rotational inertia of the partitioned synchronized grid decreases, leading to prominent frequency stability issues.
Hongchun Shu +4 more
doaj +1 more source
Dispatching mobile resources such as repair crews and mobile emergency generators is essential for the rapid restoration of distribution systems after extreme events.
Mingxuan Li +4 more
doaj +1 more source
Changes in electric network topology, such as line outages, alter fault currents, potentially causing mis-coordination among protective relays. This paper presents an adaptive protection scheme for coordinating overcurrent relays (OCRs) and distance ...
Hossein Mohammadi +2 more
doaj +1 more source
Offshore wind power offers significant advantages, including abundant wind resources; however, coastal power grids are vulnerable to damage from natural disasters such as typhoons.
Changfeng Liao +6 more
doaj +1 more source
Fault location scheme of HVDC converter based on fault loop analysis
In order to solve the problem that multiple faults in the converter area will trigger the valve short-circuit protection action, and the fault location cannot be directly located according to the protection action result, a novel converter fault location
Dalin Mu +5 more
doaj +1 more source
Researchers are increasingly interested in Non-intrusive Load Monitoring (NILM) as a cost-effective alternative to Intrusive Load Monitoring (ILM) for smart home energy monitoring. However, most NILM studies assume a fixed number of appliances and adjust
Behrooz Taheri +3 more
doaj +1 more source
CNN-based state prediction for a varying number of storage in economic dispatch
Economic dispatch (ED) is essential for power system operations. However, the large-scale energy storage (ES) integration introduces numerous binary state variables into ED formulations.
Xiang Pan +3 more
doaj +1 more source
The supplementary damping controller (SDC) in the doubly fed induction generator (DFIG) is to suppress the angular oscillations among synchronous generators (SGs).
Shenghu Li, Nan Qi
doaj +1 more source
Australia aims to achieve net zero emissions by 2050, with an interim target of reducing emissions to 43% below 2005 levels by 2030. Electrification of industry processes currently reliant on fossil fuels is a necessary step to achieve these emission ...
Mehdi Aghaei Meybodi, Andrew C. Beath
doaj +1 more source