Results 131 to 140 of about 511,439 (299)
Log file‐based quality assurance method for respiratory gating system
Abstract Background As medical linear accelerator technology advances, enabling higher dose rate deliveries, hypofractionation regimens has increased. This necessitates respiratory gating systems that synchronize radiation delivery with tumor position, requiring simple rigorous quality assurance (QA) to ensure treatment accuracy and patient safety ...
Wonjoong Cheon+7 more
wiley +1 more source
Modelling of X-ray tube spot size and heel effect in Arion [PDF]
X-rays produced in X-ray tubes originate from a focal spot on the target material. This spot is not infinitely small, but has a finite size. This finite size of the spot will affect the radiographic projections taken during X-ray Compted tomography.
Boone, Matthieu+4 more
core
Accounting for TLD response to CBCT protocols in external beam radiotherapy dose monitoring
Abstract Purpose LiF thermoluminescent dosimeters (TLDs) are commonly used in radiation therapy to verify the delivered dose. Examples include dose verification for complicated treatment setups or cardiovascular implantable electronic devices (CIEDs). TLDs may be present for both the pre‐treatment imaging kilovoltage (kV) beam and the megavoltage (MV ...
Andrew J. White+5 more
wiley +1 more source
Clinical outcomes of posterior scleral reinforcement in Chinese high myopia children
We aim to observe the posterior scleral reinforcement (PSR) clinical outcomes of children with high myopia and analyze the retinal vessel alteration before and after PSR by using angiography optical coherence tomography (angio-OCT).
Haiyun Ye+4 more
doaj +1 more source
X-ray induced acoustic computed tomography
X-ray imaging has proved invaluable in medical diagnoses and non-destructive testing (NDT) in the past century. However, there remain two major limitations: radiation harm and inaccessibility to the sample.
P. Samant, L. Trevisi, X. Ji, L. Xiang
doaj
Abstract The establishment of guidelines and curriculum standards for medical physics residency training is a critical component of setting expectations and competencies for the profession. Since the last publication of these standards, residency training has become integrated into the eligibility criteria for most medical physics certification bodies.
Jonathon A. Nye+16 more
wiley +1 more source
Fast Projection Matching for X-ray Tomography
X-ray 3D tomographic techniques are powerful tools for investigating the morphology and internal structures of specimens. A common strategy for obtaining 3D tomography is to capture a series of 2D projections from different X-ray illumination angles of ...
Chun-Chieh Wang+5 more
doaj +1 more source
Abstract Purpose This study aims to evaluate how different gantry angles, breathing rates (BPM), cine image speeds, and tracking algorithms affect beam on/off latency and the subsequent impact on target dose for a 0.35T MR‐Linac with a 6 MV FFF beam.
Mateb Al Khalifa+4 more
wiley +1 more source
Reciprocal space x-ray computed tomography
Three-dimensional reciprocal space mapping (3D-RSM) offers crucial insights into the intricate microstructural properties of materials, including spatial domain distribution, directional long-range ordering, multilayer-substrate mismatch, layer tilting ...
Arturas Vailionis+2 more
doaj +1 more source
Energy dependence of the GAFCHROMIC LD‐V1 in the diagnostic radiographic modalities
Abstract The GAFCHROMIC LD‐V1 radiochromic film is widely used in dosimetry because it can provide high‐resolution two‐dimensional dose distributions without processing. This study aimed to evaluate the response characteristics at different effective energies, from the low‐energy range of mammography to the high‐energy range of computed tomography. Net
Tatsuhiro Gotanda+9 more
wiley +1 more source