Results 271 to 280 of about 1,757,096 (355)

The effect of multi‐leaf collimator leaf width on VMAT treatment plan quality

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The advent of volumetric modulated arc therapy (VMAT) in radiotherapy has made it one of the most commonly used techniques in clinical practice. VMAT is the delivery of intensity modulated radiation therapy (IMRT) while the gantry is in motion, and existing literature has shown it has decreased treatment delivery times and the ...
Gregory Sadharanu Peiris   +3 more
wiley   +1 more source

Effects of cardiac motion on dose distribution during stereotactic arrhythmia radioablation treatment: A simulation and phantom study

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Cardiac motion may degrade dose distribution during stereotactic arrhythmia radioablation using the CyberKnife system, a robotic radiosurgery system. This study evaluated the dose distribution changes using a self‐made cardiac dynamic platform that mimics cardiac motion. Methods The cardiac dynamic platform was operated with amplitudes
Takayuki Miyachi   +6 more
wiley   +1 more source

Just 1-min exposure to a pure tone at 100 Hz with daily exposable sound pressure levels may improve motion sickness. [PDF]

open access: yesEnviron Health Prev Med
Gu Y   +10 more
europepmc   +1 more source

Multi‐institutional study on image quality for a novel CBCT solution on O‐ring linac

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Introduction This work presents a multi‐institutional study on image quality provided by a novel cone beam computed tomography (CBCT). The main goal is to investigate the consistency of imaging performance across multiple institutions.
Luis Agulles‐Pedrós   +11 more
wiley   +1 more source

JACMP 2020–2024

open access: yes
Journal of Applied Clinical Medical Physics, EarlyView.
Susan L. Richardson
wiley   +1 more source

Evaluation of the dose reduction effect of crystalline lens exposure in cone‐beam computed tomography with bismuth eye shield for image‐guided radiation therapy: An anthropomorphic phantom study

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract This study aimed to evaluate the dose‐exposure reduction effect of a crystalline lens with a bismuth eye shield using cone‐beam computed tomography (CBCT) for head image‐guided radiation therapy. The ocular surface dose of the head phantom (THRA‐1) is defined as a crystalline lens exposure dose and is measured using a radiophotoluminescence ...
Tatsuya Yoshida   +5 more
wiley   +1 more source

Relationship Between Muscle Tone and Elasticity: Simultaneous Quantitative Assessment Using Train-of-Four Monitoring and Continuous Shear Wave Elastography During Anesthesia Induction-A Prospective Observational Study. [PDF]

open access: yesDiagnostics (Basel)
Shitara H   +13 more
europepmc   +1 more source

Home - About - Disclaimer - Privacy