Transconjunctival vitrectomy: preliminary data using the TSV-25 Millennium System [PDF]
PURPOSE: To report the preliminary surgical results of pars plana vitrectomy with a transconjunctival technique using the TSV-25 Millennium system. METHODS: Twenty consecutive patients (20 eyes) that underwent transconjunctival vitrectomy with the TSV-25
Alcântara, Simone +2 more
core +3 more sources
Avaliação da contaminação bacteriana de produtos oftálmicos em uso em consultórios e centDa Roscirúrgicos hospitalares. [PDF]
Trabalho de Conclusão de Curso - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Departamento de Clínica Cirúrgica, Curso de Medicina, Florianópolis ...
Pereira, Filipe José
core
The objective of this study was to compare the accuracy between two applanation tonometers, Tono-Pen XL® and Perkins®, in horses and cattle. The eyes of 20 horses and 20 cattle conscious and healthy were evaluated for the in vivo study and both eyes of 5
Silvia Franco Andrade +7 more
doaj
Será o Implante de iStent® uma Cirurgia do Canal de Schlemm? Avaliação por OCT Spectral Domain de Segmento Anterior [PDF]
Introdução: O iStent® “trabecular micro-bypass stent modelo GTS100R/L” tem resultados comprovados na cirurgia do glaucoma de ângulo aberto. Descrito como cirurgia ab interno do canal de Schlemm, visa criar um bypass entre a câmara anterior e este canal ...
Cunha, JP +5 more
core
Estudo comparativo entre os valores de pressão intraocular aferidos por tonômetros de aplanação(tono-penavia®) e rebote (tonovetplus®)em gatos sadios [PDF]
The ophthalmic examination constitutes an important part of the clinical evaluation in routine medical care for felines, considering the diversity of systemic conditions that can be manifest through ocular signs that affect intraocular pressure (IOP),
Souza, João Lucas Tenório de
core
Comparação entre os valores de pressão intraocular aferidos por tonômetros de aplanação (Tono-Pen AVIA®) ede rebote (Tonovet Plus®) e determinação dos valores dereferência para a pressão intraocular e Teste lacrimal de Schirmer em coelhos Mini Lion Head hígidos [PDF]
Intraocular pressure (IOP) and tear production rate are essential parameters that must be evaluated during the ophthalmological examination. The Schirmer tear test and tonometry are the tests that measure the production of the precorneal tear film ...
Viega, Ismael de Oliveira
core
Correlation among Waist Circumference and Central Measures of Blood Pressure. [PDF]
Guimarães Filho GC +2 more
europepmc +1 more source
FUNDAMENTO: A rigidez arterial é uma variável preditora de morbimortalidade e um possível marcador de lesão vascular. Sua avaliação não invasiva por tonometria radial e análise do índice de incremento (r-AI) permite identificar os pacientes expostos a um
Renan Oliveira Vaz-de-Melo +9 more
doaj
Longitudinal Changes in Physical Activity Levels and Cardiovascular Risk Parameters in Patients with Symptomatic Peripheral Artery Disease. [PDF]
Monteiro F +6 more
europepmc +1 more source
Vascular Aging and Arterial Stiffness. [PDF]
Oliveira AC +9 more
europepmc +1 more source

