Correlação entre a variação diurna da pressão intraocular, amplitude de pulso e propriedades estruturais corneanas [PDF]

open access: yes, 2009
PURPOSE: The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma ...
Doi, Larissa Morimoto   +3 more
core   +2 more sources

Comparison of Rebound Tonometry, Perkins Applanation Tonometry and Ocular Response Analyser in Mucopolysaccharidosis Patients

open access: yesPLOS ONE, 2015
To investigate the feasibility and to compare three devices measuring intraocular pressure (IOP) in mucopolysaccharidosis patients (MPS): iCare rebound tonometer (RT), Perkins applanation tonometer (PAT) and ocular response analyzer (ORA).MPS patients who underwent at least two examinations out of: RT, PAT and ORA at the same visit were identified and ...
Wasielica-Poslednik, Joanna   +6 more
openaire   +6 more sources

The Accuracy of Accredited Glaucoma Optometrists in the Diagnosis and Treatment Recommendation for Glaucoma [PDF]

open access: yes, 2007
Background/aims: To compare the diagnostic performance of accredited glaucoma optometrists (AGO) for both the diagnosis of, and decision to treat glaucoma with that of routine hospital eye care against a reference standard of expert opinion, i.e ...
Azuara-Blanco, Augusto   +4 more
core   +3 more sources

Treatment chronic macular edema in Vogt-Koyanagi Harada syndrome with dexamethasone intravitreal implant: description of three case [PDF]

open access: yes, 2015
Purpose: To report our experience with dexamethasone intravitreal implant (Ozurdex, DEX implant) in the chronic cystic macular edema (ME )with Vogt-Koyanagi-Harada (VKH) Syndrome. Method: A retrospective chart review of three patients with (VKH) treated
Albanese, Giorgio   +5 more
core   +1 more source

Rapid and Accurate Pressure Sensing Device for Direct Measurement of Intraocular Pressure. [PDF]

open access: yes, 2020
PurposeIntraocular pressure (IOP) is the primary modifiable risk factor for glaucoma. Current devices measure IOP via the dynamic response of the healthy cornea and do not provide the accurate IOP measurements for patients with altered corneal ...
Camp, Andrew   +4 more
core  

The usefulness of CorvisST Tonometry and the Ocular Response Analyzer to assess the progression of glaucoma [PDF]

open access: yesScientific Reports, 2017
AbstractCorneal Visualization Scheimpflug Technology (CST) and Ocular Response Analyzer (ORA) measurements were carried out in 105 eyes of 69 patients with primary open-angle glaucoma. All patients had axial length (AL), central corneal thickness (CCT), intraocular pressure (IOP) with Goldmann applanation tonometry (GAT) and eight visual fields (VF)s ...
Kazunori Hirasawa   +6 more
openaire   +3 more sources

Effect of Uveal Melanocytes on Choroidal Morphology in Rhesus Macaques and Humans on Enhanced-Depth Imaging Optical Coherence Tomography. [PDF]

open access: yes, 2016
PurposeTo compare cross-sectional choroidal morphology in rhesus macaque and human eyes using enhanced-depth imaging optical coherence tomography (EDI-OCT) and histologic analysis.MethodsEnhanced-depth imaging-OCT images from 25 rhesus macaque and 30 ...
Cunefare, David   +7 more
core   +1 more source

Consistency of Ocular Palpation Tonometry with Goldman Applanation Tonometry and Its Reproducibility by Separate Examiners

open access: yesBeyoglu Eye Journal, 2018
INTRODUCTION[|]Elevated intraocular pressure (IOP) remains to be the best known modifiable risk factor for glaucoma. Ocular palpation tonometry (OPT) is an old, fast and simple method for IOP measurement. Our aim is to investigate accuracy, reproducibility of ocular palpation tonometry and its suitability to be used for screening purposes.[¤]METHODS ...
Muhittin Taşkapili   +4 more
openaire   +4 more sources

Dynamic contour tonometry vs. non-contact tonometry and their relation with corneal thickness [PDF]

open access: yes, 2016
The purpose of this study is to evaluate the concordance between intraocular pressure (IOP) values obtained with a dynamic contour tonometer (DCT) and a non-contact tonometer (NCT) in healthy patients and to investigate the effect of central corneal ...
Briceño, Adriana   +2 more
core   +2 more sources

Ocular Pulse Amplitude in Healthy Subjects as Measured by Dynamic Contour Tonometry [PDF]

open access: yesArchives of Ophthalmology, 2006
To test whether dynamic contour tonometry yields ocular pulse amplitude (OPA) measurements that are independent of corneal thickness and curvature, and to assess variables of observer agreement.In a multivariate cluster analysis on 223 eyes, the relationship between central corneal thickness, corneal curvature, axial length, anterior chamber depth ...
Michael A. Thiel   +3 more
openaire   +3 more sources