Review on Dynamic Contour Tonometry and Ocular Pulse Amplitude [PDF]
Intraocular pressure (IOP) measurement is the cornerstone of the management of glaucoma patients. The gold standard for assessing IOP is Goldmann applanation tonometry (GAT). Recently, the dynamic contour tonometer (DCT) has become available. While both devices provide reliable IOP measurements, the results are not interchangeable.
Koen, Willekens +6 more
openaire +3 more sources
Tonographic Effect of Ocular Response Analyzer in Comparison to Goldmann Applanation Tonometry
The tonographic effect is a phenomenon of intraocular pressure (IOP) reduction following repeated tonometry. This study examines whether the tonographic effect occurs following IOP measurement performed with Ocular Response Analyzer (ORA).Both eyes of 31 glaucoma patients and 35 healthy controls underwent nine IOP-measurements performed with GAT and ...
Martin Zimmermann +4 more
openaire +5 more sources
Ocular Tonometry and Sporadic Creutzfeldt - Jakob disease (sCJD): A Confirmatory Case-Control Study [PDF]
To evaluate the hypothesis that sporadic Creutzfeldt-Jakob disease (sCJD) may be transmitted through ocular tonometry.The infectious agent of sCJD may be present in the cornea prior to clinical symptoms. Cornea infectiousness has been documented by cornea transplants in guinea pigs and humans.
Davanipour, Zoreh +6 more
openaire +3 more sources
A comparison of the NCT Reichert R7 with Goldmann applanation tonometry and the Reichert ocular response analyzer [PDF]
P>Purpose:The aim of this study was to evaluate the accuracy of intraocular pressure (IOP) values from the new non-contact tonometer (NCT) Reichert R7 by comparing results with those from Goldmann applanation tonometry (GAT) and the Reichert Ocular ...
Acosta +31 more
core +2 more sources
Comparison of Rebound and Applanation Tonometry in Eyes With Focal Corneal Edema. [PDF]
ABSTRACT Objective To determine the effect of corneal edema on intraocular pressure (IOP) readings and their accuracy and precision when obtained with handheld rebound and applanation tonometers. Animals and Procedures IOP readings from areas of focal corneal edema were compared to those from clear cornea in 10 eyes of 7 glaucomatous cats in vivo using
Kiland JA +7 more
europepmc +2 more sources
Tonometry by Ocular Response Analyzer in Keratoconic and Warpage Eyes in Comparison with Normal Eyes
Purpose: To compare intraocular pressure (IOP) values measured by ocular response analyzer (ORA) in contact lens-induced corneal warpage, normal, and keratoconic eyes.
Fateme Alipour +4 more
semanticscholar +1 more source
Intraocular Pressure Measurement after Penetrating Keratoplasty
Assessing the intraocular pressure is a difficult but crucial task in the follow-up of patients that have undergone penetrating keratoplasty. Early recognition of elevated intraocular pressure and/or glaucoma and establishment of the appropriate ...
Otilia-Maria Dumitrescu +3 more
doaj +1 more source
Initial experience in self-monitoring of intraocular pressure. [PDF]
Background/aims: Diurnal variation in intraocular pressure (IOP) is a routine assessment in glaucoma management. Providing patients the opportunity to perform self-tonometry might empower them and free hospital resource.
Dabasia, P. +4 more
core +2 more sources
Comparison of dynamic contour tonometry and noncontact tonometry in ocular hypertension and glaucoma [PDF]
To assess the agreement in the measurement of intraocular pressure obtained by dynamic contour tonometer (DCT) and noncontact tonometer (NCT) in patients with glaucoma and ocular hypertension, to investigate the effect of corneal thickness on pressure readings by both instruments, and to assess the reproducibility of dynamic contour tonometer.NCT and ...
M, Erdurmus +3 more
openaire +2 more sources
Topical Omidenepag Isopropyl Lowers Intraocular Pressure in Normal and Glaucomatous Cats: A Pilot Study. [PDF]
ABSTRACT Purpose To evaluate the effects of topical prostaglandin E2 receptor 2 (EP2) agonist, omidenepag isopropyl (OMDI), on intraocular pressure (IOP) and pupil diameter (PD) in normal cats and cats with feline congenital glaucoma (FCG). Animals Studied Ten FCG cats and 8 normal cats.
Oikawa K +5 more
europepmc +2 more sources