Glaucoma case finding and management among optometrists in Ghana and Nigeria. [PDF]

open access: yesOptom Vis Sci
Amoah-Smith O   +3 more
europepmc   +1 more source
Some of the next articles are maybe not open access.

Related searches:

Reproducibility of 5 Methods of Ocular Tonometry

Ophthalmology Glaucoma, 2019
To evaluate the agreement between Goldmann applanation tonometry (GAT; Haag-Streit, Bern, Switzerland) and several portable tonometers that could be used for glaucoma screening programs.Evaluation of a diagnostic test.Three hundred twenty-one eyes of 168 participants seeking treatment at the glaucoma clinic of a tertiary eye hospital in India ...
Anne E. Kutzscher   +9 more
openaire   +3 more sources

Effect of Central Corneal Thickness and Corneal Hysteresis on Tonometry as Measured by Dynamic Contour Tonometry, Ocular Response Analyzer, and Goldmann Tonometry in Glaucomatous Eyes

Journal of Glaucoma, 2008
The dynamic contour tonometer (DCT; Pascal tonometer) and the Ocular Response Analyzer (ORA) are novel tonometers designed to measure intraocular pressure (IOP) independent of corneal properties and central corneal thickness (CCT), respectively. We wanted to compare the corneal compensated IOP (IOPcc) as measured by ORA with IOP values measured by DCT ...
Annette, Hager   +9 more
semanticscholar   +4 more sources

Comparing Applanation Tonometry and Rebound Tonometry in Glaucomatous and Ocular Hypertensive Eyes

European Journal of Ophthalmology, 2011
Purpose TO describe Goldmann applanation tonometer (GAT) and rebound tonometer (RT) agreement in measuring intraocular pressure (IOP) in glaucomatous and ocular hypertensive (OH) eyes and to evaluate central corneal thickness (CCT) influence on RT readings.
Marini M.   +3 more
openaire   +4 more sources

Association of Ocular Hypotensive Medication Types with Dynamic Contour Tonometry and Goldmann Applanation Tonometry Measurements in a Glaucoma and Ocular Hypertensive Population

Journal of Ocular Pharmacology and Therapeutics, 2013
The aim of this study was to evaluate the association between different intraocular pressure (IOP)-lowering medications and IOP measurements by dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) in a glaucoma and ocular hypertensive population.In a prospective, observational case series study, 410 eyes from 410 consecutive ...
Argyrios, Tzamalis   +4 more
openaire   +3 more sources

Evaluation and Testing of Novel Ocular Tactile Tonometry Device

2014
This article describes the experimental analysis of a novel trans-scleral tonometer based on the use of multiple force sensors forming a mechanical stiffness sensor. This approach is similar to an instrumented form of digital palpation tonometry in which manual palpation is used to conclude the stiffness, and hence, the intraocular pressure of the eye.
E. T. Enikov   +3 more
openaire   +2 more sources