Seating accuracy of removable partial denture frameworks fabricated by different digital workflows in comparison to conventional workflow

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose To evaluate the seating accuracy of removable partial denture (RPD) frameworks fabricated by two digital workflows involving selective laser melting (SLM) in comparison to the conventional workflow. Materials and Methods A Kennedy class III modification 1 partially edentulous mandibular arch was used as a master model.
Andrea Korkes   +10 more
wiley   +1 more source

Optical stability of 3D‐printed and milled zirconia after artificial aging and immersion in liquids: An in vitro study

open access: yesJournal of Prosthodontics, EarlyView.
ABSTRACT Purpose To assess the impact of artificial aging and immersion in common liquids on the optical properties of 3D‐printed and milled zirconia. Materials and Methods Monolithic zirconia discs (N = 100) were fabricated using two methods: 3Y‐TZP for milling (e.max ZirCAD LT BL, Ivoclar Vivadent) and printable 3Y‐TZP material (LithaCon 3Y 230) for ...
Athanasios E. Rigos   +4 more
wiley   +1 more source

A Rare Case of Bilateral Maxillary Supplemental Lateral Incisors. [PDF]

open access: yesCureus
Singla D   +4 more
europepmc   +1 more source

Surface gloss and micro‐CT analysis of additively and subtractively manufactured resin composites and zirconia after simulated tooth brushing with different bristle types and toothpaste formulations: An in vitro study

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose This study aimed to evaluate the effects of simulated tooth brushing with different bristle types and two toothpaste formulations on the surface gloss and structural integrity of additively (AM) and subtractively (SM) manufactured resin composites and zirconia.
Ahmet Faruk Ertürk   +3 more
wiley   +1 more source

The accuracy of static computer‐aided implant surgery in four central incisor post‐extraction morphologies: An in vitro study

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose To evaluate the accuracy of guided surgery in a healed ridge and various maxillary anterior extraction sockets. Materials and Methods Forty radiopaque urethane resin bone models simulating the maxillary right central incisor were fabricated and divided into four groups (n = 10 each).