Results 131 to 140 of about 14,055 (177)
A deep learning-driven cataract screening model derived from multicenter real-world dataset. [PDF]
Cui Z, Cheng Y, Pan S, Zhu Y, Dai W.
europepmc +1 more source
Izdelava 3D modela fasade z uporabo videotahimetra Topcon GPT-7003i in Topcon-ove programske opreme
openaire +1 more source
Nonexudative Macular Neovascularization in Age-Related Macular Degeneration.
Thottarath S +6 more
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Assessment of the accuracy and reliability of the Topcon CT80 non‐contact tonometer
Australasian journal of optometry, The, 2006The reliability of non-contact tonometers has been reported extensively in the literature. This study was designed to assess reliability of the new Topcon CT80 non-contact tonometer in normotensive subjects, using the Goldmann tonometer as the standard.The accuracy of the Topcon CT 80 non-contact tonometer was assessed by comparing its IOP assessments ...
Kelechi Ogbuehi
exaly +3 more sources
Plating on TOPCon as a Way to Reduce the Fabrication Costs of i-TOPCon Solar Cells
202037th European Photovoltaic Solar Energy Conference and Exhibition; 179 ...
Steinhauser, Bernd +11 more
openaire +1 more source
Clinical evaluation of the Topcon CT10 tonometer
International Ophthalmology, 1988We evaluated the clinical use of the Topcon CT10 non-contact tonometer in our outpatient clinic. Compared to the Goldmann applanation it is useful and reliable in screening glaucoma patients.
C, Verdoorn, A F, Deutman
openaire +2 more sources
A clinical evaluation of the Topcon RM6000 autorefractor
Clinical and Experimental Optometry, 1989The Topcon RM6000 autorefractor was evaluated by assessing the repeatability of its results and the extent of their agreement with the findings of conventional subjective refraction.
David B. Elliott, Robert D. Wilkes
openaire +1 more source
Range ratio of topcon radiation thermometers
SICE Annual Conference 2007, 2007Topcon 0.65 mum and 0.9 mum radiation thermometers are used as the standard thermometers at high temperatures. These radiation thermometers employ three to five ranges to cover their whole temperature ranges. The range ratios of these thermometers influence largely on the calibration uncertainty.
null Fumihiro Sakuma, null Laina Ma
openaire +1 more source
The Topcon DL-101C Digital Level
Australian Surveyor, 2000Even though the Topcon digital levels have been on the market since 1994, very little has been reported on the working principle of these instruments and on the results achieved with them. This paper discusses the operating principle of the Topcon digital level DL-101C and explains how the staff reading and the sighting distance are derived from the ...
openaire +1 more source
Comparison of Topcon Optical Coherence Tomography and Ultrasound Pachymetry
Optometry and Vision Science, 2012ABSTRACT Purpose To establish within‐rater repeatability and minimum measurements required for reliable assessment of central corneal thickness (CCT) using Topcon three‐dimensional OCT‐2000 (Topcon Medical Systems, Oakland, NJ) Fourier‐domain optical coherence tomography (FD‐OCT) and to test ...
Luke Cameron, Northey +2 more
openaire +2 more sources

