Results 91 to 100 of about 609,557 (246)

Toric phakic implantable collamer lens for correction of astigmatism: 1-year outcomes [PDF]

open access: yes, 2011
Erik L MertensMedipolis Eye Centre, Antwerp, BelgiumPurpose: The purpose of this study was to assess predictability, efficacy, safety and stability in patients who received a toric implantable collamer lens to correct moderate to high myopic astigmatism ...
Erik Mertens, Erik L Mertens
core   +1 more source

Surgical technique for management of isolated lenticular coloboma with high corneal astigmatism

open access: yesIndian Journal of Ophthalmology, 2018
We describe a surgical technique for the correction of isolated congenital lenticular coloboma associated with high corneal astigmatism. Transscleral fixation of the capsular bag with a single eyelet Cionni capsular tension ring was followed by in-the ...
Simar Rajan Singh   +3 more
doaj   +1 more source

Evaluation of Tilt and Decentration of Intraocular Lens After Combined Femtosecond Laser‐Assisted Cataract Surgery and Vitrectomy

open access: yesJournal of Ophthalmology, Volume 2026, Issue 1, 2026.
Purpose To evaluate the changes in tilt and decentration prior to and following microincision vitrectomy and femtosecond laser‐assisted cataract surgery (FLACS) using a 7 mm intraocular lens (IOL). Methods Patients were grouped by surgical method: conventional phacoemulsification surgery and vitrectomy without gas (Group A: 27 eyes), conventional ...
Tomoyuki Watanabe   +6 more
wiley   +1 more source

On Higher Syzygies of Projective Toric Varieties [PDF]

open access: yes, 2006
Let A be an ample line bundle on a projective toric variety X of dimension n (≥ 2). It is known that the d-th tensor power A⊗d embedds X as a projectively normal variety in Pr := P(H0(X,L⊗d)) if d ≥ n − 1.
Shoetsu Ogata, Ogata, Shoetsu
core   +1 more source

Real-world refractive outcomes of toric intraocular lens implantation in a United Kingdom National Health Service setting

open access: yesBMC Ophthalmology, 2018
Background With increasing availability of toric intraocular lenses (IOL) for cataract surgery, real-world refractive outcome data is needed to aid the counselling of patients regarding lens choice. We aim to assess the outcomes of toric intraocular lens
Kanmin Xue   +5 more
doaj   +1 more source

Intraoperative capsular marking for toric intraocular lens placement

open access: yesTaiwan Journal of Ophthalmology, 2020
Preoperatively, the surgeon instills two drops of 0.5% proparacaine and then marks the 0° and 180° points at the limbus using a Gentian violet marker and 26G needle edge. Intraoperatively, after phacoemulsification and irrigation and aspiration of the cortex are complete, the surgeon inspects the previously marked 0°-180° points on the limbus.
Harinder Singh Sethi, Mayuresh P Naik
openaire   +3 more sources

Scleral Fixation of a One-Piece Toric Intraocular Lens [PDF]

open access: yesJournal of Refractive Surgery, 2013
PURPOSE: To describe a novel technique for toric intraocular lens (IOL) repositioning and fixation in the absence of adequate capsular support. METHODS: Case report and literature review.
Matthew E, Emanuel   +2 more
openaire   +2 more sources

Rotational stability of toric intraocular lenses by lens model and haptic design: systematic review and single-arm meta-analysis

open access: yesJournal of cataract and refractive surgery
In a meta-analysis of 51 published studies including 4863 eyes, the pooled mean absolute postoperative rotation of all toric IOLs was 2.36 degrees (95% CI, 2.08-2.64).
Eric S. Li   +3 more
semanticscholar   +1 more source

Development and management of surgical techniques for toric intraocular lenses in patients with compromised capsular integrity

open access: yesYanke Xuebao
Astigmatism is a common form of refractive error. For patients who also have cataracts, implanting a Toric intraocular lens (Toric IOL) offers an effective solution.
CHEN Yesheng, SU Dingwang
doaj   +1 more source

Reverse Optic Capture to Stabilize a Toric Intraocular Lens [PDF]

open access: yesCase Reports in Ophthalmology, 2013
<b><i>Purpose:</i></b> To describe a technique for stabilizing a rotationally unstable toric intraocular lens (IOL). <b><i>Method:</i></b> Case report and literature review. <b><i>Results:</i></b> Surgical technique and long-term follow-up for a patient who underwent repositioning ...
Howard V. Gimbel, Anika Amritanand
openaire   +3 more sources

Home - About - Disclaimer - Privacy